Panasonic WJ-MPU955A Home Security System User Manual


 
79
Patrol Learn
1. Select a desired monitor and camera. (Refer to p. 56
Monitor Selection and Camera Selection.)
2. Display "Patrol" menu. (Refer to Step 1 and 2 of p. 77
To Recall Menu Functions.)
3. Press the F1 (Start) button.
The patrol learn setup will start.
4. Perform desired camera operations by moving the 3D
joystick or zoom wheel controller, etc.
The following controls are available for patrol learn.
Panning/Tilting (3D joystick)
Iris control (IRIS OPEN/CLOSE buttons)
Focus control (FOCUS FAR/NEAR buttons)
Zoom control (Zoom wheel controller)
Note: The available total time of patrol learn differs
depending on cameras. When the time is over, the
patrol learn setup will automatically stop.
5. To quit the patrol learn setup, press the F2 (Stop) but-
ton.
Group Preset
Note: This function is available only when Group Preset set-
ting has been established through the admin console.
(Refer to the Admin Console User's Guide.)
A Group Preset determines which monitor is to be assigned
to which camera. Therefore, monitor selection is not
required.
1. Display "GrpPre" menu. (Refer to Step 1 and 2 of p. 77
To Recall Menu Functions.)
2. Select a desired Group Preset number by pressing the
numeric buttons.
3. Press the F1 (Set) or CAM(SET) button to activate a
selected Group Preset function.
The preset position of assigned cameras will be dis-
played simultaneously on the assigned monitors.
OSD Control
1. Select a desired monitor. (Refer to p. 56 Monitor
Selection.)
2. Display "OSD" menu. (Refer to Step 1 and 2 of p. 77 To
Recall Menu Functions.)
3. Select a desired function by pressing one of the F1 to
F4 buttons.
Available buttons and functions
F1: T&D
Displays or hides the clock (time and date) display.
F2: Cam
Displays or hides the camera ID (camera number and
title) display.
F3: Gen
Displays or hides the general status display.
F4: Mon
Displays or hides the moitor status display.
Note: Refer to the illustrations in p. 63 for each OSD
item.
Digital Output
Note: This function is available only when Digital Output
setting has been established through the admin con-
sole. (Refer to the Admin Console User's Guide.)
1. Display "DigiOut" menu. (Refer to Step 1 of p. 77 To
Recall Menu Functions.)
2. Select a Digital Output number by pressing the numer-
ic buttons.
3. Press the F1 (Set) or CAM(SET) button. A one-shot
pulse will be produced, and an assigned event will be
activated.
Note: Digital Output does not support the restore func-
tion.
GrpPre : 005
Set
DigiOut: 007
Set
Patrol : 004
Start Stop
OSD : 006
T&D Cam Gen Mon