Omron FQM1-MMP21 Home Security System User Manual


 
357
Auxiliary Area Allocations Appendix D
A612 00 to 15 High-
speed
counter 1
monitor
data
Range Comparison Execution
Results Flags
Contains the CTBL(882) execution results for range comparison.
Bits 00 to 15 correspond to ranges 1 to 16.
OFF: No match
ON: Match
A613 00 to 15 Output Bit Pattern Contains the output bit pattern when a match is found for
CTBL(882) execution results for range comparison
Note If more than one match is found, an OR of the output bit
patterns with matches will be stored here.
A614 00 to 15 High-
speed
counter 2
monitor
data
Range Comparison Results Same as for high-speed counter 1 monitor data.
A615 00 to 15 Output Bit Pattern
A620 to
A621
00 to 15 Pulse Output 1 PV
Note This item applies when the operation
mode is relative pulse output, absolute pulse
output in linear mode, absolute pulse output in
circular mode, or electronic cam mode.
Contains the pulse output PV as an 8-digit hexadecimal number.
Relative mode: 00000000 to FFFFFFFF hex
Absolute linear mode: 80000000 to 7FFFFFFF hex
Absolute circular mode: 00000000 to circular maximum count
One-shot Pulse Output 1 ON Time
Note This item applies when the operation
mode is one-shot output mode.
Contains the time that the one-shot pulse output has been ON as
an 8-digit hexadecimal number.
0000 0000 to 0000 270F (unit: set by STIM(980))
Pulse Time Measurement 1
Note This item applies when the operation
mode is time measurement mode using a pulse
counter.
Contains the time measured by the pulse counter as an 8-digit
hexadecimal number.
0000 0000 to FFFF FFFF hex (unit: set by STIM(980))
A622 to
A623
00 to 15 Pulse Output 2 PV Same as for Pulse Output 1 PV.
One-shot Pulse Output 2 ON Time Same as for One-shot Pulse Output 1 ON time.
Pulse Time Measurement 2 Same as for Pulse Time Measurement 1.
A624 00 Pulse
Output 1
Status
Pulse Output Completed Flag OFF: Pulse output not completed (OFF during pulse output).
ON: Pulse output completed (ON when pulse distribution has
been completed).
01 Pulse Output Set Flag OFF: Pulse output amount not set by PULS(886).
ON: Pulse output amount set by PULS(886).
02 Target Frequency Not Reached Flag OFF: Target speed has been reached during pulse output for
PLS2(887).
ON: Decelerated before reaching the target speed during pulse
output for PLS2(887).
03 Target Comparison Flag OFF: Comparison stopped.
ON: Comparison in progress.
04 Independent Pulse Output Flag OFF: Pulses not being output or being output continuously.
ON: Pulses being output.
05 PLS2 Positioning Flag OFF: Not positioning.
ON: Positioning in progress.
06 Accelerating/Decelerating Flag OFF: No output or constant-speed output.
ON: Acceleration or deceleration in progress for ACC(888) or
PLS2(887).
07 Pulse Output Flag OFF: Pulse output stopped.
ON: Pulse output in progress.
A625 00 Pulse
Output 2
Status
Pulse Output Completed Flag Same as for Pulse Output 1 Status.
01 Pulse Output Set Flag
02 Target Frequency Not Reached Flag
03 Target Comparison Flag
04 Independent Pulse Output Flag
05 PLS2 Positioning Flag
06 Accelerating/Decelerating Flag
07 Pulse Output Flag
Address Bits Name Function