Omron FQM1-MMP21 Home Security System User Manual


 
185
Pulse Outputs Section 7-6
Set the clock speed for pulse outputs 1 and 2.
4. Create the necessary ladder programming.
Use PULS(886) to set number of output pulses for the specified port.
Use SPED(885) to start pulse output control without acceleration/deceler-
ation from the specified port.
Use INI(880) to stop pulse output from the specified port.
Use PRV(881) to read the pulse output PV of the specified port.
Pulse Outputs with Acceleration/Deceleration
This procedure shows how to use PULS(886) and ACC(888) to generate a
pulse output with acceleration or deceleration. The number of output pulses
cannot be changed during positioning.
1,2,3... 1. Determine pulse output port.
Select pulse output 1 or 2.
2. Wire the output.
Output: CW and CCW
Output power supply: 5 V DC
3. Make the necessary System Setup settings (Pulse Output Tab Page
Op-
eration Mode).
Set the pulse output operation mode (in the Pulse Output Tab Page
Operation Mode) to relative pulse output, absolute linear pulse output, or
absolute circular pulse output.
Set the clock speed for pulse outputs 1 and 2.
4. Create the necessary ladder programming.
Use PULS(886) to set number of output pulses for the specified port.
Use ACC(888) to start pulse output control with acceleration or decelera-
tion from the specified port (acceleration and deceleration are specified
separately).
Use INI(880) to stop pulse output from the specified port.
PULS
INI
SPED
A621 A620
A623 A622
A624
A625
CW
CCW
CW
CCW
Pulse output function
Pulse output mode
System Setup
Pulse output
port 1
Pulse output
port 2
Single-phase output
without acceleration/
deceleration
(fixed duty ratio)
Start
output
Ladder program Ladder program
Set the number of
output pulses.
Stop pulse output.
Output mode:
CW/CCW, independent/continuous
Target frequency
Start pulse output
Refresh status (once each cycle
just after instruction execution)
Refresh PV (once each cycle)
Pulse output status Pulse output PV
Port 1Port 1
Port 2Port 2
SET PULSES
MODE CONTROL
SPEED OUTPUT