Emerson 8600 Gas Heater User Manual


 
116
Reference Manual
00809-0100-4860, Rev BC
Appendix B: Approval information
January 2013
Approval information
B.1.4 European certifications (ATEX)
I.S. certification
EN 60079-0: 2012
EN 60079-11: 2012
I1 Certification No. Baseefa12ATEX0179X
ATEX Marking II 1 G
Ex ia IIC T4 Ga (-60 °C Ta +70 °C)
Ui = 30 VDC
Ii= 185 mA
Pi = 1.0 W
Ci = 0uF
Li = 0.97 mH
Special conditions for safe use (X)
1. When fitted with 90V transient suppressors, the equipment is not capable of passing
the 500V isolation test. This must be taken into account upon installation.
2. The enclosure may be made from aluminum alloy and given a protective polyurethane
paint finish; however, care should be taken to protect it from impact or abrasion when
located in Zone 0.
3. When the equipment is installed, particular precautions must be taken to ensure taking
into account the effect of process fluid temperature, that the ambient temperature of
the electrical housing of the equipment meets the marked protection type
temperature range.
Type ‘n’ certification
EN 60079-0: 2012
EN 60079-11: 2012
EN 60079-15: 2010
N1 Certification No. Baseefa12ATEX0180X
ATEX Marking II 3 G
Ex nA ic IIC T5 Gc (-40 °C Ta +70 °C)
Maximum Working Voltage = 42 Vdc
Special conditions for safe use (X)
1. When fitted with 90V transient suppressors, the equipment is not capable of passing
the 500V isolation test. This must be taken into account upon installation.
2. When the equipment is installed, particular precautions must be taken to ensure,
taking into account the effect of process fluid temperature, that the ambient
temperature of the electrical housing of the equipment meets the marked protection
type temperature range.
Flameproof certification
EN 60079-0: 2009
EN 60079-1: 2007
EN 60079-11: 2007
60079-26: 2007