Emerson 8600 Gas Heater User Manual


 
98
Reference Manual
00809-0100-4860, Rev BC
Appendix A: Reference Data
January 2013
Specifications and Reference Data
A.3 Typical flow ranges
Tab le A -5 - Tabl e A -9 show typical flow ranges for some common process fluids with default
filter settings. Consult your local sales representative to obtain a computer sizing program that
describes in greater detail the flow range for an application.
Table A-5. Typical pipe velocity ranges for 8600D
(1)
(1)
Tab le A -5 is a reference of pipe velocities that can be measured for the standard Rosemount 8600D. It does not consider density limitations, as described in
Tab le A -2 and Tab l e A - 3. Velocities are referenced in schedule 40 pipe.
Process Line
Size
Liquid Velocity Ranges Gas Velocity Ranges
(Inches/ DN) Vortex Meter (ft/s) (m/s) (ft/s) (m/s)
1/ 25 8600DF010 0.70 to 25.0 0.21 to 7.6 6.50 to 250.0 1.98 to 76.2
1
1
/2 / 40 8600DF015 0.70 to 25.0 0.21 to 7.6 6.50 to 250.0 1.98 to 76.2
2/ 50 8600DF020 0.70 to 25.0 0.21 to 7.6 6.50 to 250.0 1.98 to 76.2
3/ 80 8600DF030 0.70 to 25.0 0.21 to 7.6 6.50 to 250.0 1.98 to 76.2
4/ 100 8600DF040 0.70 to 25.0 0.21 to 7.6 6.50 to 250.0 1.98 to 76.2
6/ 150 8600DF060 0.70 to 25.0 0.21 to 7.6 6.50 to 250.0 1.98 to 76.2
8/ 200 8600DF080 0.70 to 25.0 0.21 to 7.6 6.50 to 250.0 1.98 to 76.2
Table A-6. Water Flow Rate Limits for the Rosemount 8600D
(1)
(1)
Tab le A -6 is a reference of flow rates that can be measured for the standard Rosemount 8600D. It does not consider density limitations, as described in Ta ble A -2
and
Tab le A -3 .
Process Line Size
Vortex Meter
Minimum and Maximum Measurable Water Flow Rates*
(Inches/ DN) Gallons/Minute Cubic Meters/Hour
1/ 25 8600DF010 2.96 to 67.3 0.67 to 15.3
1
1
/2 / 40 8600DF015 4.83 to 158 1.10 to 35.9
2/ 50 8600DF020 7.96 to 261 1.81 to 59.4
3/ 80 8600DF030 17.5 to 576 4.00 to 130
4/ 100 8600DF040 30.2 to 992 6.86 to 225
6/ 150 8600DF060 68.5 to 2251 15.6 to 511
8/ 200 8600DF080 119 to 3898 27.0 to 885
*Conditions: 77 °F (25 °C) and 14.7 psia (1.01 bar absolute)
Table A-7. Air Flow Rate Limits at 59 °F (15 °C)
Process
Pressure
Flow Rate
Limits
Minimum and Maximum Air Flow Rates
for line sizes 1-in./DN 25 through 2-in./DN 50
1-in./DN 25 1
1
/2-in./DN 40 2-in./DN 50
Rosemount 8600D Rosemount 8600D Rosemount 8600D
ACFM ACMH ACFM ACMH ACFM ACMH
0 psig
(0 bar G)
max
min
79.2
9.71
134
16.5
212
18.4
360
31.2
349
30.3
593
51.5
50 psig
(3,45 bar G)
max
min
79.2
3.72
134
6.32
212
8.76
360
14.9
349
14.5
593
24.6
100 psig
(6,89 bar G)
max
min
79.2
2.80
134
4.75
212
6.58
360
11.2
349
10.8
593
18.3
150 psig
(10,3 bar G)
max
min
79.2
2.34
134
3.98
212
5.51
360
9.36
349
9.09
593
15.4