Chapter 3 - Robot Installation
42 AdeptSix 300CR Robot Instruction Handbook, Rev. A
Figure 3-6. Grounding Method for Robot
3.9 Environmental Requirements
The environmental conditions of the area in which the robot is installed must satisfy the
conditions listed below:
Ambient temperature must be from 0° to +45° C
No moisture should be present (20 to 80% RH)
Level of the mounting plane for installation must be 0.5 mm or less
System must be isolated from excessive electrical interference or noise (plasma)
The area must be free from:
Dust, soot, and water
Corrosive gases and liquids, as well as explosive gases
Excessive vibration (less than 0.5 G)
WARNING: Wiring must be performed by authorized or
certified personnel. Failure to observe this caution may
result in fire or electric shock.
M8 Bolt - for grounding
(provided at factory)
5.5 mm
2
or more
A