York R-410A ZH/ZJ/ZR Series Air Conditioner User Manual


 
528150-YTG-G-1210
Johnson Controls Unitary Products 85
115°F 125°F
2125
77 102.2 10.3 39.0 35.2 25.4 - - - 95.6 11.4 36.2 31.0 22.6 - - -
72 93.5 10.1 60.2 50.4 40.6 30.8 - - 86.5 11.1 56.8 47.1 37.5 27.8 - -
67 84.8 10.0 81.3 65.5 55.8 46.0 36.2 - 77.4 10.9 77.4 62.1 52.4 42.7 33.1 -
62 78.5 9.9 78.5 78.5 63.8 54.0 44.2 34.4 71.8 10.8 71.8 71.8 57.3 47.7 38.0 28.3
2550
77 105.2 10.4 51.2 39.7 28.3 - - - 98.0 11.4 49.9 36.6 25.3 - - -
72 96.2 10.2 68.1 56.6 45.2 33.7 - - 88.7 11.2 64.7 53.3 41.9 30.6 - -
67 87.3 10.0 85.0 73.5 62.0 50.6 39.1 - 79.4 11.0 79.4 70.0 58.6 47.3 35.9 -
62 80.8 9.9 80.8 80.8 71.0 59.6 48.1 36.6 73.6 10.9 73.6 73.6 64.2 52.8 41.5 30.1
57 79.6 10.0 79.6 79.6 69.9 58.5 47.0 35.5 73.3 11.0 73.3 73.3 63.4 52.1 40.7 29.3
2975
77 108.2 10.4 63.4 44.3 31.1 - - - 100.5 11.4 63.7 42.3 28.0 - - -
72 99.0 10.2 76.0 62.9 49.7 36.6 - - 90.9 11.2 72.5 59.5 46.4 33.4 - -
67 89.8 10.0 88.6 81.5 68.3 55.2 42.1 - 81.4 11.0 81.4 77.9 64.8 51.8 38.7 -
62 83.1 9.9 83.1 83.1 78.2 65.1 51.9 38.8 75.4 10.9 75.4 75.4 71.0 58.0 44.9 31.9
57 81.8 10.0 81.8 81.8 77.0 63.9 50.7 37.6 75.1 11.0 75.1 75.1 70.2 57.1 44.1 31.0
3400
77 111.2 10.4 75.7 48.8 34.0 - - - 102.9 11.4 77.4 47.9 30.7 - - -
72 101.7 10.2 84.0 69.1 54.3 39.5 - - 93.1 11.2 80.4 65.6 50.9 36.1 - -
67 92.3 10.0 92.3 89.5 74.6 59.8 45.0 - 83.3 11.0 83.3 83.3 71.1 56.3 41.6 -
62 85.4 9.9 85.4 85.4 85.4 70.6 55.8 41.0 77.3 10.9 77.3 77.3 77.3 63.1 48.4 33.6
57 84.1 10.0 84.1 84.1 84.1 69.3 54.5 39.6 77.0 11.0 77.0 77.0 77.0 62.2 47.5 32.7
3825
72 102.6 10.3 89.7 73.7 57.7 41.8 - - 93.9 11.3 86.0 70.1 54.1 38.2 - -
67 93.0 10.1 93.0 91.6 79.3 63.3 47.4 - 84.0 11.1 84.0 84.0 75.6 59.7 43.8 -
62 86.1 10.0 86.1 86.1 86.1 70.1 54.2 38.2 77.9 11.0 77.9 77.9 77.9 62.3 46.4 30.5
57 84.8 10.1 84.8 84.8 84.8 68.8 52.8 36.9 77.6 11.1 77.6 77.6 77.6 61.7 45.8 29.8
4250
72 103.4 10.3 95.4 78.3 61.1 44.0 - - 94.7 11.4 91.6 74.5 57.4 40.3 - -
67 93.8 10.1 93.8 93.8 84.0 66.9 49.7 - 84.7 11.1 84.7 84.7 80.2 63.1 46.0 -
62 86.8 10.0 86.8 86.8 86.8 69.7 52.6 35.4 78.6 11.1 78.6 78.6 78.6 61.5 44.4 27.3
57 85.5 10.1 85.5 85.5 85.5 68.3 51.2 34.1 78.2 11.2 78.2 78.2 78.2 61.2 44.1 27.0
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZR102 (8.5 Ton) Cooling (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F) Return Dry Bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65