Vista N7227V5 Home Security System User Manual


 
171
SECTION 17
Zone Lists
(
81 Menu Mode)
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
About Zone List Menu Mode
Zone List Displays
••••••••••••••••••••••••••••••••••••••••••••••••••
About Zone List Menu Mode
Zone List Menu mode is used to program zone lists for output devices (programmed in
80
Menu mode). Refer to the Programming Form worksheet (
81) that programs the Zone Lists
for Output Devices.
To program the zone lists, press
81 while in Program mode.
Zone List Displays
Zone List No.
(00 = Quit) 01
Enter the Zone List Number 01, 02, or 03 you want to program (or
00 to end these entries).
Press [
]
to advance.
In the following displays, zone list 01 has been selected for
programming
.
01 Enter Zn Num.
(00 = Quit) 00
Enter each zone number to add to the zone list by first entering the
zone number, then
(for example, 01
, 02
, 03
). After all zones
desired are entered, press
00
to advance.
IMPORTANT:
Do not include fire zones in zone lists that are used
to STOP relay actions.
01 Del Zn List?
0 = No 1 = Yes 0
To delete the zone list, enter
1
(Yes). All zones in the zone list are
deleted automatically, and programming returns to the first
screen.
To save the zone list, enter
0
(No) to advance.
01 Delete Zone?
0 = No 1 = Yes 0
To save the entire zone list, enter
0
(No). Programming returns to
the first screen.
To delete a zone or zones in a zone list, enter
1
(Yes) to advance.
01 Zn to Delete?
(00 = Quit) 00
Enter each zone to be deleted from the list, followed by
. After all
zones to be deleted are entered, enter
00
to return to the first
screen so that another list can be programmed, if desired.
Any list may include any or all of the system's zone numbers
except
zone 08.
A zone list can be assigned to more than one output relay.