Vista N7227V5 Home Security System User Manual


 
VISTA-10SE Installation and Setup Guide
13-2
Type 05
Trouble by Day/
Alarm by Night
Zone type 05 is usually assigned to a zone that contains foil-protected doors
or windows; or covers a sensitive area (e.g., stock room, drug supply room,
etc.) It can also be used on a sensor or contact in an area where immediate
notification of an entry is desired.
Zone Characteristics
:
Provides an instant alarm when armed in AWAY, STAY, INSTANT, or
MAXIMUM (night) mode.
Provides a latched trouble sounding from the keypad and, if desired, a
central station report during the disarmed state (day).
Type 06
24-hour Silent Alarm
Zone type 06 is usually assigned to a zone containing an Emergency button.
Zone Characteristics:
Sends a report to the central station but provides no keypad display or
sounding.
Type 07
24-hour Audible Alarm
Zone type 07 is usually assigned to a zone containing an Emergency button.
Zone Characteristics:
Sends a report to the central station, and provides alarm sounds
externally and at the keypad.
Type 08
24-hour
Auxiliary Alarm
Zone type 08 is usually assigned to a zone containing a button for use in
personal emergencies or to a zone containing monitoring devices (e.g., water
or temperature sensors, etc.).
Zone Characteristics:
Sends a report to the central station and provides an alarm sound at the
keypad. (No bell output is provided and there is no keypad timeout.)
Type 09
Supervised Fire
5806/5807/5808
01000-020-V0
Zone type 09 can be assigned to any wireless zone used as a fire zone. This
zone type is always active and cannot be bypassed.
Zone Characteristics:
Bell output will pulse when this zone type is alarmed.
Type 10
Interior w/Delay
Zone type 10 is bypassed when the panel is armed in the STAY or INSTANT
mode.
Zone Characteristics:
Entry delay #1 (with programmed entry time) when armed in the AWAY
mode.
Entry delay begins whenever sensors in this zone are violated,
regardless of whether an entry/exit delay zone was tripped first.
No entry delay when armed in the MAXIMUM mode.
Exit delay regardless of the arming mode selected.