Vista N7227V5 Home Security System User Manual


 
131
SECTION 13
Zone Response Type Definitions
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
Zone Type Definitions
••••••••••••••••••••••••••••••••••••••••••••••••••
Zone Type Definitions
You must assign to each zone a zone type that defines the way in which the system responds
to faults in that zone. Zone types are defined below.
Type 00
Zone Not Used
Zone type 00 is used to program a zone that is not used.
Type 01
Entry/Exit Burglary
01000-017-V0
Zone type 01 is usually assigned to sensors or contacts on primary entry and
exit doors.
Zone Characteristics:
Entry delay #1 is programmable from 0-99 seconds (field *35).
Exit delay is independently programmable from 0-99 seconds (field *34).
Exit and entry delays when armed in AWAY or STAY mode.
No entry delay when armed in INSTANT or MAXIMUM mode.
Exit delay regardless of the arming mode selected.
Type 03
Perimeter Burglary
01000-018-V0
Zone type 03 is usually assigned to all sensors or contacts on exterior doors
and windows.
Zone Characteristics:
Instant alarm when armed in AWAY, STAY, INSTANT, or MAXIMUM
mode.
Type 04
Interior, Follower
5890
01000-019-V0
Zone type 04 is usually assigned to a zone covering an entry area (i.e.: foyer,
lobby, or hallway) that one must pass upon entry (after faulting the
entry/exit zone) to reach the keypad. It provides an instant alarm if the
entry/exit zone is not violated first, and protects an area in the event an
intruder has hidden on the premises before the system is armed, or gains
access to the premises through an unprotected area.
Zone Characteristics:
Delayed alarm (using the programmed entry/exit time) if entry/exit (type
01) or interior-with-delay (type 10) zone is faulted first.
Instant alarm in all other situations.
Active when armed in AWAY or MAXIMUM mode.
Bypassed automatically when armed in STAY or INSTANT mode.