Vista N7227V5 Home Security System User Manual


 
VISTA-10SE Installation and Setup Guide
14-8
RESTORE
REPORT CODES
(
70
75)
70 ALARM RESTORE REPORT CODE
(See box on previous page). For expanded or 4+2 reporting, a 2nd
digit is automatically sent, and is the same as the 2nd digit of the
zone Alarm Report code programmed in field
56.
71 TROUBLE RESTORE REPORT CODE (2-Digit Entry)
(See box on previous page.) This is sent when a trouble in a zone is
restored.
72 BYPASS RESTORE REPORT CODE (2-Digit Entry)
(See box on previous page.) This is sent when a zone that has been
bypassed is unbypassed.
73 AC RESTORE REPORT CODE (2-Digit Entry)
(See box on previous page.) Reports with Subscriber No.
74 LOW BAT RESTORE REPORT CODE (2-Digit Entry)
(See box on previous page.) Reports with Subscriber No.
75 RF XMTR. LOW BATTERY RESTORE CODE (2-Digit Entry)
(See box on previous page.) This is sent when a transmitter that
previously sent in a low-battery message has sent a message
indicating it no longer has a low-battery condition.
80 OUTPUT RELAYS
This is an Interactive Menu mode that is applicable only if 4204
relays are to be used (3 in field
25). See the RELAY OUTPUT
DEVICES section for a detailed programming procedure. Also refer to
the OUTPUT RELAYS TABLE FOR FIELDS
80 and
81 in the
Programming Form inserted in this manual.
81 ZONE LISTS FOR OUTPUT DEVICES
This is an interactive menu mode that is applicable only if field
25 is
programmed for a 4204 relay. Refer to the RELAY OUTPUT
DEVICES section for a detailed programming procedure. Also refer to
the ZONE LISTS FOR OUTPUT RELAYS table for
81 in the
Programming Form inserted in this manual.
82 CUSTOM ALPHA EDITING
See the ALPHA DESCRIPTOR PROGRAMMING section for
procedure.
91 OPTION SELECTION (1-Digit Entry)
Enter 4 if an Audio Alarm Verification (AAV) unit is connected in
the system; enter 8 for Exit Delay Restart; enter # +12 for AAV +
Exit Delay Restart. Enter 0 if an AAV unit is not being used.
For UL installations, the AAV option must be disabled (0).
Important: AAV should not be used when Paging or Alarm Reports
are being sent to a secondary number. If this is done, the call to the
secondary number by the communicator after the Alarm Report will
prevent the AAV from taking control of the telephone line, and the
AAV Listen-in session cannot take place.
92 NUMBER OF REPORTS IN ARMED PERIOD (1-Digit Entry)
This option can be used to limit the number of messages (Alarm and
Alarm Restore Reports) sent to the central station in an armed
period. 0 limits reports to a total of 10; 1 allows an unlimited
number of reports.
UL installations: Must select "1."