8.3.2 Connection Setting
Turn on and off the printer.
Setting connector options
[Procedure]
1) Click the option buttons
Use the option button to select the printer and WHM
connection.
Available printer options are ON or OFF.
Printer connection
Off (No connection): Turns the printing function off. (Default)
On (Connection) : Turns the printing function on.
8.3.3 Reliability Function
Turn on and off the automatic reboot function as backup
and the database backup function.
Setting automatic reboot and database backup function
[Procedure]
1) Click the option button
Use the option button to select the Automatic Reboot
function and Database Backup function.
Automatic reboot setting
Off (Deactivate) : Does not automatically reboot.
(Default)
On (Activate) : Automatically reboots.
Backup setting
Off (Deactivate) : Do not back up the database. (Default)
On (Activate) : Back up the database.
2) Select the reboot interval using the “
/
” buttons.
When automatic reboot was set to On, select the automatic reboot day using the “
/
” buttons.
The setting range is the 7th thru 31st day after booting. The initial value is the 31st day.
3) Set the output folder.
When database backup was set to On, set the database folder to be backed up using the Browse
button. The initial value is “C:\TG2000\databackup”.
* Set the folder to be backed up to an HDD drive different from the C: drive.
Note:
Data cannot be printed if this option is OFF.
Maintenance Tip
Manually restart the TG-
2000A application and Windows 2000/XP OS on a regular basis
(once a week). (Perform the restarting operation during the period from 08:00 to 21:45.)
Note:
When Windows 2000/XP OS is used
continuously without restarting, system errors may
accumulate. Thus it is necessary to restart both TG-2000A and the OS.
The automatic restart function serves to insure that the system restart is done on a regular basis.
If there is an error during the
automatic restart, the system must be restarted manually. Since
there is a possibility of the error not being detected,
it is recommended to periodically restart the
system manually.
When automatic reboot is set to [ON], Windows reboots automatically at 06:35 on the 7th to
31st
day after booting. (The number of days depends on the set value.)
The system configuration, history, and charge data databases are backed up. The trend and
display characters databases are not backed up.
Connection settings
Reliability Function Settings
window