Galil DMC-1700 Home Security System User Manual


 
40 • Chapter 2 Getting Started DMC-1700/1800
Instruction Interpretation
#A;DP0 Label; Define current position as zero
PR 4000 Initial position
SP 2000 Set speed
BGX Move X
AMX Wait until move is complete
WT 500 Wait 500 ms
#B
V1 = _TPX Determine distance to zero
PR -V1/2 Command X move ½ the distance
BGX Start X motion
AMX After X moved
WT 500 Wait 500 ms
V1= Report the value of V1
JP #C, V1=0 Exit if position=0
JP #B Repeat otherwise
#C Label #C
EN End of Program
To start the program, command
XQ #A Execute Program #A
This program moves X to an initial position of 1000 and returns it to zero on increments of half the distance. Note,
_TPX is an internal variable which returns the value of the X position. Internal variables may be created by
preceding a DMC-1700/1800 instruction with an underscore, _.
Example 15 - Linear Interpolation
Objective: Move X,Y,Z motors distance of 7000,3000,6000, respectively, along linear trajectory. Namely, motors
start and stop together.
Instruction Interpretation
LM XYZ Specify linear interpolation axes
LI 7000,3000,6000 Relative distances for linear interpolation
LE Linear End
VS 6000 Vector speed
VA 20000 Vector acceleration
VD 20000 Vector deceleration
BGS Start motion
Example 16 - Circular Interpolation
Objective: Move the XY axes in circular mode to form the path shown on Fig. 2-8. Note that the vector motion
starts at a local position (0,0) which is defined at the beginning of any vector motion sequence. See application
programming for further information.
Instruction Interpretation
VM XY Select XY axes for circular interpolation
VP –4000,0 Linear segment
CR 2000,270,-180 Circular segment