4 - 33
4 AUXILIARY AND APPLIED FUNCTIONS
4.7.2 Access range of the communications via network
(1) Network configuration via the MELSECNET/10(H) or the Ethernet
(a) It can access the other CPU via the network from the programming software
(GX Developer, SW6RN-GSV
P, etc.) of the personal computer connected
with the CPU or serial communication module in USB/RS-232.
(b) It can access the other CPU via the network from the programming software
in the personal computer by connecting the personal computer equipped
with Ethernet to MELSECNET/10(H) or Ethernet board to the Ethernet to
MELSECNET/10(H) or Ethernet.
(c) The access range of above (1) and (2) can be accessed to 8 network points
by setting the routing parameter to the control CPU of the network module
and the CPU which connected the personal computer.