Mitsubishi Electronics Q172HCPU Home Security System User Manual


 
3 - 35
3 COMMON PARAMETERS
3.3.14 Notch shape selection 2
This parameter is used to select the machine resonance suppression filter 2 (Notch
shape selection 2).
1: Invalid
Notch depth selection
0
1
2
3
Notch width selection
Setting value Depth
Gain
Shallow
Deep
-40dB
-14dB
-8dB
-4dB
0
1
2
3
Setting value
Width
Wide
Standard
2
3
4
5
0
Machine resonance suppression filter 2 selection
2: Valid
3.3.15 Low pass filter selection
This parameter is used to select the low pass filter.
Low pass filter selection
00 0
0: Automatic setting
1: Manual setting (Setting value of "PB18: Low pass filter setting")
3.3.16 Slight vibration suppression control selection
This parameter is used to select the slight vibration suppression control and PI-PID
switching.
00
Slight vibration suppression control selection
0: Invalid
1: Valid
PI-PID control switch over selection
0: PI control is valid
3: PI control is always valid