Honeywell 5820XL Smoke Alarm User Manual


 
Programming
151209 7-41
7.7.5 Miscellaneous Options 2
Through this programming option you can turn the strobe synchronization during silence
feature On or Off, and select the control panel to report events by zone or by point.
To edit miscellaneous options 2:
1. Enter the installer code.
2. Press or to display the main menu.
3. Select for Program Menu.
Display reads: Initializing
Please wait . . .
4. Select for System Options.
5. Select for Miscellaneous Options 2.
7.7.5.1 Synchronize Strobes Active During Silence
When "SYNC Strbs w/ Sil:" is Selected as Y (Yes) then strobes will continue to flash when the
system is silenced and will stop flashing when the system is reset.
Note: The "SYNC Strbs w/ Sil:" only functions with outputs that use a synchronized output pattern.
6. Press the or arrow to toggle this selection between Y (Yes) or N (No).
7. Press or to make your selection and move to the next programming option.
Note: See Section 7.4.1.4 for more information about Synchronization protocol choices.
7.7.5.2 Auto Display Oldest Event
When this feature is programmed Y (Yes) then the oldest un-acknowledge event will
automatically display on the control panel and remote annunciators after there has been no
activity on any system touchpad for two minutes.
8. Press the or arrow to toggle this selection between Y (Yes) or N (No).
9. Press
or to make your selection and move to the next programming option.
7.7.5.3 Report by Zone or by Point
When the "Report by" option is set to Zone, then the control panel will report events by zone.
If Point is selected then the control panel will report events by point.
10. Press the or arrow to toggle this selection between Zone or Point.
11. Then press or . See Section 9 for reporting codes.