Conair CHS-810 Plumbing Product User Manual


 
Pre-Setting of Rotating Knives,
Granulator with Open Cutter
Knives can only be pre-set on granulators with open cutter.
The knives are pre-set on a jig.
The jig is not included when the
granulator is delivered, but is
a very practical accessory.
Setting Up the Knives
NOTE: The knives must be
sharpened before pre-setting.
When the machine is delivered, the jig is calibrated
against the set screws welded solid in the granulator cutter.
The jig gives the correct clearance of 0.008 - 0.012 in.
(0.20 - 0.30 mm).
Screw the adjustment screws on a rotating knife in somewhat.
Put knife in the jig, with the edge downwards.
Put an 0.008in. (0.20 mm) feeler gauge between the adjustment screws
and the rear of the jig.
Unscrew the adjustment screws
until the feeler gauge begins to bind.
The pre-setting is now completed
and the knife can be installed in the cutter.
Installation of Pre-Set Knives.
NOTE: Each time the knives are changed, the
fastening screws must be replaced by new ones.
Install one pair of knives at a time.
Clean the knife attachments.
Install one pair of knives
Install the attachment screws with washers loosely.
Adjust the pair of knives against the outer edges of the cutter housing.
11
Accessories
Accessories l 11-3