Conair CHS-810 Plumbing Product User Manual


 
5-2 l Installation
Installation
Read through the whole of Section 5 before installing the machine! All instructions
must be followed in the given order to avoid injury or damage.
Be careful with the knives, they are sharp and can cause personal injury.
The granulator must only be connected to the mains by a competent
electrician.
Pre-Start Checks
The unpainted parts of the machine are protected with oil prior to delivery
and transport Clean the granulator from rust protection agent before it is
used.
Check the knife clearance and tightening torque on the bolts for the
knives. Refer to installation of knives in Section 7.
Two Hours After First Start
Check the knife clearance again and the tightening torque of the knife retentio
screws. Check the screws for both the fixed and rotating knives.