V-belt Adjustment
• Remove the upper panel on the
right-hand side of the granulator.
• CHS series-noise encapsulated
machine, remove the rear guard
plate above the motor and open the door.
• Undo and remove the extraction pipe.
Alt. CHS series-machine with extraction fan, undo the quick coupling on
the outlet pipe stub.
• Remove the granule bin.
• Undo the motor screws (A) lightly, 4 pcs.
• Adjust the belt tension by increasing/reducing the distance of the motor to
the cutter pulley, using the motor adjustment screws (B), 2 pcs.
• Tighten the motor screws (33.2lb-ft [45 Nm] torque)
• If the belt tension is adjusted, the belt need to be re-checked after 20 - 30
hours at full load.
Transmission
(continued)