Conair CHS-810 Plumbing Product User Manual


 
8 Undo and remove the socket cap screws (E) on the rear knife
support rule (F).
NOTE: Hold the fixed knife and support rule before removing the last screw.
9 Lift out the fixed knife together with the support rule.
10 Clean the knife location.
11 Put the support rule back loosely.
Installing the Knives
The knife attachments for both the fixed and rotating knives must be carefully
cleaned.
First install the rear, fixed knife
1 Install the rear fixed knife on the knife
attachment.
2 Screw in the socket cap screws (E), so
that the support rule (F) lightly supports
the knife.
3 Press the knife firmly into the knife
attachment to bed it down.
NOTE: The screws in the rear of the
knife attachment are bonded in place.
NOTE: The knife has a fixed position
and no adjustment may be done.
4 Tighten screws (E), with alternating
tightening torque to 29.5lb-ft (40 Nm).
Install the rotating knives.
NOTE: When the rotating knives are installed in a granulator with open cutter, the knives must
always be pre-set before installation!
Pre-setting of knives for a granulator with open cutter is best done in a special pre-
setting jig. The jig is not included when the machine is delivered, but is a very
practical accessory which can be ordered. The jig and knife pre-setting is described
in Section 11.
E F
Service l 7-3
7
Service