Conair CHS-810 Plumbing Product User Manual


 
3-4 l Function Description
Safety System
The granulator has a safety system to prevent access to dangerous
components during operation.
The granulator has knives that rotate at high speed. The granulator is
therefore equipped with a safety system to avoid personal
injury.The safety system must not be changed or modified
under any circumstances.
If the safety system of the granulator is changed or
modified, the machine can be dangerous to use,
presenting a serious risk of personal injury.
All care and maintenance to the safety system of the
granulator must be carried out by personnel with the
necessary knowledge.
If the safety system of the granulator is modified in any way,
Conair’s responsibility under the Machinery Directive ceases
to apply.
Only Conair spare parts must be used to replace safety
components.
Emergency Stop
The granulator has an emergency stop on the control panel.
It can also be equipped with extra emergency stops.
The emergency stop is activated by pressing the button. Reset
by turning the button in the direction of the arrow (counter-
clockwise).
Safety Switch
The granulator has safety switches of the
position switch type with breaking key:
If a secured position is changed or when a breaking key
is undone,
it will break the current and the granulator stops.
This granulator has 2 safety switches:
1 at the hopper and 1 at the screen box
Check the wiring diagram (Section 9) to see how many safety switches the granulator is
equipped with.
Breaking key
Safety
switches
Emergency
stop
Main switch