Installation l 5-3
5
Installation
Electrical Connection
The granulator should be connected by a competent electrician.
• Connect the granulator to the main power supply. The wiring diagram
indicates the fuse sizes, see Section 9.
• The granulator is delivered with electrical equipment connected for clock-
wise phase rotation. Check with a phase sequence indicator and connect
the granulator with clockwise phase rotation.
Check the direction of rotation of the granulator motor:
• Make sure that the main switch beneath the control panel is “On” (1).
• Check that the emergency stop is not activated.
• Check that the star knobs on the hopper and screen box locks are fully
tightened to stop.
• Undo and remove the upper panel on the right hand side of the granulator.
• Press “Start”
• Check that the granulator motor rotates in the direction indicated by the
arrow on the cutter pulley.
• Granulator with blower, – check that the direction of rotation of the blower
corresponds with the arrow on the cover.
NOTE: The blower blows even if the direction of rotation is wrong.
• Granulator with conveyor belt, – check the direction of the
conveyor belt.
If any direction of rotation should be incorrect:
• Press the stop button.
• Switch off the main switch.
• Switch two incoming phases.
✐