Conair CHS-810 Plumbing Product User Manual


 
Installation l 5-3
5
Installation
Electrical Connection
The granulator should be connected by a competent electrician.
Connect the granulator to the main power supply. The wiring diagram
indicates the fuse sizes, see Section 9.
The granulator is delivered with electrical equipment connected for clock-
wise phase rotation. Check with a phase sequence indicator and connect
the granulator with clockwise phase rotation.
Check the direction of rotation of the granulator motor:
Make sure that the main switch beneath the control panel is “On” (1).
Check that the emergency stop is not activated.
Check that the star knobs on the hopper and screen box locks are fully
tightened to stop.
Undo and remove the upper panel on the right hand side of the granulator.
Press “Start”
Check that the granulator motor rotates in the direction indicated by the
arrow on the cutter pulley.
Granulator with blower, – check that the direction of rotation of the blower
corresponds with the arrow on the cover.
NOTE: The blower blows even if the direction of rotation is wrong.
Granulator with conveyor belt, – check the direction of the
conveyor belt.
If any direction of rotation should be incorrect:
Press the stop button.
Switch off the main switch.
Switch two incoming phases.