Fault-Finding
The granulator does not start
Check that the emergency stop is not activated.
Reset by turning the button(s) in the direction of the arrow
(counterclockwise).
Check that the hopper is properly closed.
The granulator will not start if the hopper not is properly closed.
Tighten the star knobs properly to stop.
Check that the screen box is properly
closed.
The granulator will not start, if the screen
box not is properly closed.
Tighten the star knobs properly to stop.
Check the overload circuit breaker
for the motor.
The motor has an overload circuit
breaker, F1, in the distribution box, which
trips if you jam or over-load the motor.
This is indicated in the window (A) which shows “0”.
Reset, press the “Reset” button (B).
Check that there is no material left in the granulator before restarting.
Granulator with blower (CHS series-machine with extraction fan).
Check the blower overload circuit breaker. The granulator will not start
if the blower does not start.The blower motor has an overload circuit
breaker, F2, in the distribution box, which trips if you jam or overload
the blower.This is indicated in the window (A) which shows “0”.
Reset, press the “Reset” button (B).Check that there is no material left
in the granulator before restarting.
A
B
6-6 l Operation and Daily Maintenance