Conair CHS-810 Plumbing Product User Manual


 
Service l 7-5
Then install the front, fixed knife
16 Install the knife in the knife attachment.
17 Screw in the socket cap screws (C) and
tighten so that the support rule (D) lightly
supports the knife.
18 Press the knife firmly into the knife
attachment.
NOTE: The screws in the rear of the
knife attachment are bonded in place.
NOTE: The knife has a fixed position
and no adjustment may be done.
19 Tighten the screws (C), with alternating
tightening torque to 29.5 lb-ft (40 Nm).
20 Carefully check that all rotating knives
can pass the front fixed knife.
If any knife can not pass the front fixed knife freely
– undo the screws (C) and press the knife firmly into the knife
attachment.
21 Check the clearance of each rotating knife with a feeler gauge The
clearance should be 0.008 - 0.012 in. (0.20 - 0.30 mm), check at
the outer edges of the knives.
22 Re-check the tightening torque of all rotating knives (55.3 lb-ft
[75 Nm]; granulator with open cutter 162.3 lb-ft [220 Nm]).
23 Re-check the tightening torque of the front and rear fixed knives
(29.5 lb-ft [40 Nm]).
D C
7