Balcar R410A Air Conditioner User Manual


 
145
HOW TO USE THE TIMER CORRECTLY
1. Operation procedure
2. Turn on the power supply of the air conditioner
Turn on the power supply of the air conditioner connected with a program weekly
timer. (For cooling and heating, do not turn off the power supply for compressor
heating.)
3. Setup of the present time
Set the present time
(Example: Case that the present time is 11:45.)
Power ON
Turn on the power of the air conditioner.
1
While push
SET
button push
HH
button
to select “hour” of the present time.
While push
SET
button each pushing
HH
button, change sequently.
While keep
SET
button pushed, continu-
ous pushing
HH
button makes fast forward.
(Example: Leave the finger at display of
11, you can set 11 oclock.)
When release
SET
button, the hour is
set, and
mark changes flashing to
light.
2
While push
SET
button push
MM
button to select “minutes” of the present time.
While push
SET
button, each pushing
MM
button change sequently.
While keep
SET
button pushed continuous, pushing
MM
button makes fast forward.
(Example: Leave the finger at display of 45 you can set 45 minutes.)
When release
SET
button, the minutes are set, and make changes flashing to
light.
CAUTION
The time cannot be changed only when
HH
button or
MM
button pushed.
If 30 seconds have passed while the button is flashing without pushing
DAY
or
HH
/
MM
buttons, the display returns automatically to the original display (Normal display).
In this case, repeat the procedure from the 1st step.
Program weekly timer set up
Setup of the present time
¯
Setup of the present day of the week
¯
Setup of the program operation for a week
WEEKLY TIMER
ERROR
SuMoTuWeThFrSa
PROGRAM1
PROGRAM2
PROGRAM3
CHECK
PROGRAM
SET
DAY
HH MM
CLEAR
CANCEL
1
2
2
1
NAME AND OPERATION OF EACH PART
1
Day select button
The day of the week is selected.
Each pushing,
mark moves in order of
Sunday
Monday Tuesday
Wednesday Thursday Friday
Saturday.
2
Program button
This button is used to set up the
contents of the program operation.
3
Hour/Minute button
This button is used to set the present
time and ON/OFF time.
4
Timer set button
This button is used to set the day of the
week, hour, minute, holiday, and ON/
OFF time.
5
Cancel button
This button is used to cancel as the
holiday.
6
Check button
This button is used to confirm the
contents of the setting items.
7
Cancel button
This button is used to cancel the setting
items.
8
Display of the present day of the
week (
mark)
9
ON/OFF time display
ON/OFF time of the timer operation is
displays.
10
Operation reserve indication
(
mark)
The day of the week when the
program operation has been set is
displayed.
11
Holiday setting indication ( mark)
The holiday is displayed
(Cancel as holiday)
12
Setting error display
13
Present time display
Displays the present time displayed
with 24-hours notation.
ERROR
SuMoTuWeThFrSa
PROGRAM1
PROGRAM2
PROGRAM3
WEEKLY TIMER
ERROR
SuMoTuWeThFrSa
PROGRAM1
PROGRAM2
PROGRAM3
CHECK
PROGRAM
SET
DAY
HH MM
CLEAR
CANCEL
4
5
6
7
12
13
8 10,11
2
9
1
3
RBC-EXW21E