Mitsubishi Electronics C64 Home Safety Product User Manual


 
12. PLC Axis Control
12.3 PLC Interface
- 421 -
12.3.5 Handle Feed Axis Selection
The axis is designated for the following devices when handle feed is carried out with a PLC axis.
Device No. Signal name
Y42D HS1P 1st handle PLC axis valid
Y42E HS2P 2nd handle PLC axis valid
Y42F HS3P 3rd handle PLC axis valid
When Y42D to Y42F are ON, each handle changes to PLC axis dedication.
"Y740 to 744 and 747" for the 1st handle usually used in the control device are used for
the axis selection of each handle.
("Y748 to 74C and 7AF" for the 2nd handle, "Y750 to 754 and 757" for the 3rd handle)
PLC axes are counted as PLC such as first axis and second axis. Therefore, if you will
operate the first handle in the first axis of PLC, turn ON Y42D, Y740 to Y744 and Y747.
(Note) The handle feed magnification is also used for NC control axes.