Mitsubishi Electronics C64 Home Safety Product User Manual


 
10. Exclusive Commands 2
10.3 Tool Life Management Exclusive Command
- 369 -
(c) Tool status ..... Bits 8~F of file register Rn (such as R6358)
bit Explanation
bit 8
bit 9
bit A
bit B
Tool status (numeric data 0~4)
0: Unused tool
1: Used tool
2: Normal life tool
3: Tool error 1 tool
4: Tool error 2 tool
bit C
bit D
bit E
bit F
(Reserved)
(d) Tool status contents
When the tool status number is 0 or 1, NC assumes the tool to be available.
Tool status
number
Explanation
0
Indicates unused tool.
Normally, this state is set when tool is replaced with a new tool.
1
Indicates used tool.
When actual cutting is started, this state is set.
2
Indicates normal life tool.
When use data exceeds life data, this state is set.
3
Indicates tool error 1 tool.
When controller inputs the tool error 1 signal, this state is set.
4
Indicates tool error 2 tool.
When controller inputs the tool error 2 signal, this state is set.