6
1 BEAUTY COVER
The beauty cover snaps open and shut to hide the keypad’s keys, mode and
supervisory indicators, and the sensor location labeling area.
2 KEYPAD
Backlit keys for easy viewing in low light conditions.
For entering the user's user code (numerically or alphabetically).
Used when programming system options.
Press to activate the Automation Output.
Press to clear keypad if the wrong key is pressed.
Press for two seconds to view sensor battery and supervisory status (see
BATTERIES and RADIO indicator description).
3 24-HOUR BUTTONS
Pressing FIRE for two seconds sounds the fi re siren and sends a “fi re” message
to a central monitoring station through the digital communicator (if the system
is monitored).
Pressing EMERGENCY for two seconds sounds the emergency siren and sends
an “emergency” message to a central monitoring station through the digital
communicator (if the system is monitored).
Both work even when system is disarmed.
IMPORTANT: For personal emergency use only. Not for use as a UL Listed
Medical Alert System.
4 SYSTEM SUPERVISORY INDICATORS
Shows the current status of the system.
POWER LIGHT
Glows when AC power is on.
Blinks when AC power is off and backup battery is installed.
Blinks when the backup battery is low, recharging or missing.
Off when AC power is off and no backup battery is installed (system disabled).
BATTERIES LIGHT
Blinks when one or more sensors have a low battery.
Press for two seconds to view sensor status. Sensor status indicator for any
sensor with a low battery will light along with the BATTERIES indicator.
Switch to Test Mode after replacing the sensor battery and completely test the
system (see Test Mode). Switching to Test Mode clears the low battery indication.
RADIO LIGHT
Blinks when one or more sensors have not reported status during the eight hour
status time period.
Press for two seconds to view sensor status. Sensor status indicator for any
sensor that has not reported in will light along with the TROUBLE indicator.
Switch to Test Mode after servicing the sensor and completely test the system
(see Test Mode). Switching to Test Mode clears the trouble indication.
5 MODE INDICATORS
The indicators next to the mode keys light to show the current system mode.
HOME indicator will blink during Secure Exit and Home Instant modes.
AWAY indicator will blink during the exit delay in the Away Mode.
6 MICROPHONE (OPTIONAL)
Location for the high sensitivity microphone included with the Model RSM-2
speaker/microphone kit.
Detects room audio when communicator is reporting to the Central Station
in 2-way audio mode (Model VB-2 digital voice response module and RSM-2
speaker/microphone kit must be installed).
7 SENSOR STATUS INDICATORS
Blacked-out sensor status indicators are only visible when lit.
Indicate the status of each of the system's wireless sensors and hardwired
loops.
Indicators show which doors and windows are open.
Indicators fl ash to display sensors that have caused an alarm.
Stick-on labels are provided to identify the custom sensor locations.
8 SYSTEM STATUS INDICATORS
Shows the current status of the system.
READY LIGHT
Lights when all system sensors are closed.
Shows that the system is ready to be armed.
The system can be armed without the READY indicator being lit, if sensors are
bypassed either manually or automatically.
ARMED LIGHT
Blinks during the exit delay.
Lights when the system is fully armed.
TROUBLE LIGHT
Lights when the system has detected supervisory trouble.
Supervisory trouble can be caused by power, sensor low battery, or sensor radio
supervision conditions.
Press for one second then view the system supervisory and status indicators
to determine the origin of the trouble.
9 MODE BUTTONS
Used to operate the system.
OFF
Off Mode disarms the system.
Switching to Off Mode stops the alarm siren.
Multiple Beeps sound and sensor status indicators fl ash if an alarm has
occurred.
Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.
CHIME
Chime Mode disarms the system.
Switching to Chime Mode stops the alarm siren.
Multiple Beeps sound and sensor status indicators fl ash if an alarm has
occurred.
Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.
Chime Mode is for monitoring doors and windows.
Use this mode as an “automatic door chime” when at home.
Opening any protected door or window causes the keypad(s) to “ding-dong”.
HOME
Home Mode arms the perimeter sensors, but not the interior sensors.
Use this mode when anyone is staying behind.
Interior motion detectors and interior door sensors are not armed.
Home secure mode makes all delayed perimeter sensors instant.
Secure exit mode starts an exit delay while remaining in Home Mode.
Re-entering during the exit delay restarts the exit delay (one time only).
AWAY
Away Mode arms the entire system.
Use this mode when leaving home.
Door sensors set for delayed will have a time delay that allows the user to
leave and enter the premises without sounding the alarm.
Re-entering during the exit delay restarts the exit delay (one time only).
Entry Delay Beeps warn the user to disarm the system before the siren
starts.
TEST
Test Mode is for testing the system sensors.
All sensor status lights blink when the Test Mode is entered.
Each sensor status light will stop blinking when its sensor is tested.
Hold the TEST button down to test all of the keypad's indicator lights.
10 SOUNDER
Makes unique sounds for burglary, fi re and emergencies.
Alarm sirens stop automatically after fi ve minutes.
Sounds advisory tones to confi rm keystrokes from the keypad.
Sounds mode selection tones.
Sounds alarm memory tones.
Beeps when Automation Output is activated.
The Control Panel has terminals available for an external siren.
11 SPEAKER (OPTIONAL)
Location for the speaker included with the Model RSM-2 speaker/microphone
kit.
Sounds voice operating prompts and audio from the Central Station (Model
VB-2 digital voice response module and Model RSM-2 required).
4. HARDWIRED KEYPAD FEATURES
4
3
5
9
6
7
8
10
1
2
11