Linear DUAL 824 Home Security System User Manual


 
33
AUTOMATION OUTPUT MODE DURING ALARM
The factory setting causes the Automation
Output to fl ash if it is programmed to activate
during or after an alarm.
NOTE: For the Automation Output to activate
during or after an alarm, that function must be
enabled with Programming Step 71 or 72.
STEP #68 The output can be programmed to be a steady
output using this step.
AUTOMATION ACTIVATION TONE
The factory setting causes the keypad(s) to
sound a “Bing” when the Automation Output is
activated by pressing the
key, or when it's
triggered with a two-button remote control.
STEP #69 This sound can be silenced using this step.
REMOTE CONTROL & HARDWIRE ARM/DISARM CHIRP
When arming with the portable remote control
or with a hardwired loop programmed as arm/
disarm (sensor Function #9), the factory setting
causes the keypad(s) to “chirp” once when
armed, twice when disarmed, and three times
when arming with sensors bypassed.
STEP #70 These chirps can be silenced using this step.
NOTE: If these chirps are silenced, it is
recommended to program the Automation Output
to be active when the system is armed, so a light
can be triggered displaying the arming status of
the system.
AUTOMATION OUTPUT ON DURING AND AFTER ALARM
The factory setting causes the Control Panel's
Automation Output to activate when pressing the
key, or when it's triggered with a two-button
remote control.
STEP #71 The Control Panel can be programmed to
activate the Automation Output during and after
any alarms as well as when normally triggered
using this step.
NOTE: The output will continue until the fl ashing
sensor status lights are cleared.
AUTOMATION OUTPUT ON DURING ALARM
The factory setting causes the Control Panel's
Automation Output to activate when pressing the
key, or when it's triggered with a two-button
remote control.
STEP #72 The Control Panel can be programmed to
activate the Automation Output during alarms as
well as when normally triggered using this step.
NOTE: The Automation Output can be programmed
to fl ash or be steady during alarm, see
Programming Step 68.
PROGRAMMING STEP #68
ENTERS STEP NUMBER
0 FOR FLASHING OUTPUT
1
FOR STEADY OUTPUT
STORES VALUE - 1 BING
PROGRAMMING STEP #69
ENTERS STEP NUMBER
0 FOR BING TONE OFF
1
FOR BING TONE ON
STORES VALUE - 1 BING
PROGRAMMING STEP #70
ENTERS STEP NUMBER
0 FOR CHIRPS OFF
1
FOR CHIRPS ON
STORES VALUE - 1 BING
PROGRAMMING STEP #71
ENTERS STEP NUMBER
0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING &
AFTER ALARM
STORES VALUE - 1 BING
PROGRAMMING
STEP #72
ENTERS STEP NUMBER
0 FOR STANDARD TRIGGER
1
FOR OUTPUT DURING ALARM
STORES VALUE - 1 BING