Linear DUAL 824 Home Security System User Manual


 
37
GENERAL COMMUNICATOR OPTIONS
COMMUNICATOR ENABLE
The factory setting for the Control Panel disables
the communicator. If the system is going to be
a non-monitored, local alarm only, leave the
communicator disabled.
STEP #107 If the system is going to be monitored by a
Central Station, enable the communicator with
this programming step.
2-WAY AUDIO
When the Model VB-2 voice module is installed,
the communicator can provide 2-way audio
capability.
The audio module can be programmed for
listen-only, 2-way manual operation (using a
pushbutton telephone at the Central Station), and
2-way full duplex hands free operation.
Refer to the VB-2 installation instructions for
details on operating the audio module.
NOTE: The Model VB-2 digital voice response
module must be installed for this option to
function.
The factory setting for the VB-2 audio module is OFF.
STEP #76 The audio module can be set for (1) listen-only, (2)
2-way manual, (3) 2-way full duplex using this step.
NOTE: For safety, 2-way audio will not activate if
the system is disarmed with the duress code.
NOTE:Units programmed for two-way duplex can
still be controlled manually by pressing the “1” or
“3” key. In addition, the Central Station can return
the unit to two-way duplex by pressing the “8” key.
VOICE RESPONSE
The Control Panel can be programmed to allow
the keypad(s) speaker to play audio produced by
the VB-2 digital voice response module.
This selection can also be used when a remote
speaker is connected to the Control Panel.
The factory setting is to disable the keypad(s)
speaker from playing voice module audio.
STEP #78 The Control Panel can be programmed to enable
voice module audio using this step.
NOTE: Turning voice response OFF with this
programming step will only effect the audio produced
by the voice module. It will not stop the keypad(s)
speaker from sounding local sirens and tones.
NOTE: A Model VB-2 digital voice response module
must be installed for this option to function.
REMOTE LOCKOUT
The factory setting for the communicator allows
remote connection to the Control Panel with
Linear's RA-2400 Remote Access Software and
a modem (unlocked).
STEP #100 The Control Panel can be programmed to not
answer incoming calls, thereby, not allowing
remote access (locked) using this step.
PROGRAMMING
STEP #107
ENTERS STEP NUMBER
0
FOR COMMUNICATOR OFF
1 FOR COMMUNICATOR ON
STORES VALUE - 1 BING
PROGRAMMING STEP #76
ENTERS STEP NUMBER
0
FOR NO AUDIO MONITORING
1 FOR LISTEN-ONLY
2 FOR 2-WAY MANUAL
3
FOR 2-WAY FULL DUPLEX
STORES VALUE - 1 BING
PROGRAMMING
STEP #78
ENTERS STEP NUMBER
0 FOR NO VOICE RESPONSE
E
1
FOR VOICE RESPONSE
STORES VALUE - 1 BING
PROGRAMMING
STEP #100
ENTERS STEP NUMBER
0
FOR UNLOCK
1 FOR LOCK
STORES VALUE - 1 BING