Linear DUAL 824 Home Security System User Manual


 
31
FIRE SIREN TIME
The factory-set fi re siren time is fi ve minutes (UL
installation maximum).
STEP #32 The fi re siren time can be adjusted from one to
30 minutes using this step.
AUTOMATION OUTPUT TIME
The factory setting causes the Automation
Output to toggle between on and off with each
activation.
STEP #40 The Automation Output can be programmed to
turn on, then automatically turn off after one to
2500 seconds (42 minutes), or toggle on & off,
using this step.
REMOTE CONTROL & HARDWIRE ARMING LEVEL
The factory setting causes the portable remote
controls to arm to the Away Mode.
STEP #50 The portable remote controls can be changed to
arm to the Home Mode using this step.
NOTE: Changing this setting will affect all the
portable remote controls used with the system and
all hardwired loops programmed as arm/disarm
(sensor Function #9) key stations.
REMOTE CONTROL & HARDWIRE DISARMING LEVEL
The factory setting causes the portable remote
controls to disarm to the Off Mode.
STEP #51 The remote controls can be changed to disarm to
the Chime Mode using this step.
NOTE: Changing this setting will affect all the
portable remote controls used with the system and
all hardwired loops programmed as arm/disarm
(sensor Function #9) key stations.
ENTRY DELAY BEEPS
The factory setting causes the keypad(s) to beep
during Entry Delays.
STEP #61 The Entry Delay beeps can be silenced using
this step.
With the Entry Delay beeps off, the keypad(s) will
be silent after a delayed sensor is triggered until
the Entry Delay expires, then the alarm siren will
sound.
EXIT DELAY BEEPS
The factory setting causes the keypad(s) to beep
during Exit Delays.
STEP #62 The Exit Delay beeps can be silenced using this
step.
With the Exit Delay beeps off, the keypad(s) will
be silent after arming to the Away Mode until the
Exit Delay expires, then a single “Gong” tone will
sound.
PROGRAMMING STEP #32
ENTERS STEP NUMBER
TIME IN MINUTES 1 - 30
STORES VALUE - 1 BING
PROGRAMMING STEP #40
ENTERS STEP NUMBER
TIME IN SECONDS 1 - 2500
0
= TOGGLE ON & OFF
STORES VALUE - 1 BING
PROGRAMMING STEP #50
ENTERS STEP NUMBER
2 FOR HOME MODE
3
FOR AWAY MODE
STORES VALUE - 1 BING
PROGRAMMING STEP #51
ENTERS STEP NUMBER
0 FOR OFF MODE
1
FOR CHIME MODE
STORES VALUE - 1 BING
PROGRAMMING STEP #61
ENTERS STEP NUMBER
0 FOR ENTRY BEEPS OFF
1
FOR ENTRY BEEPS ON
STORES VALUE - 1 BING
PROGRAMMING STEP #62
ENTERS STEP NUMBER
0 FOR EXIT BEEPS OFF
1
FOR EXIT BEEPS ON
STORES VALUE - 1 BING