Linear DUAL 824 Home Security System User Manual


 
32
SILENT BURGLARY ALARMS
The factory setting causes audible burglary
alarms.
STEP #63 The Control Panel can be programmed for silent
burglary alarms using this step.
SILENT EMERGENCY ALARMS
The factory setting causes audible emergency
alarms.
STEP #64 The Control Panel can be programmed for silent
emergency alarms using this step.
DISABLING QUICK ARMING
The factory setting allows quick arming of the
Control Panel by pressing down the mode keys
for two seconds.
STEP #65 The Control Panel can be programmed to not
allow quick arming using this step. If quick
arming is disabled, a user code must be entered
before pressing the mode buttons.
NOTE: For commercial installations with retail
traffi c, it is recommended to disable quick arming
to prevent customers from arming the system.
NOTE: If quick arming is disabled the Home Instant
Mode is unavailable.
AUTOMATIC RESTORAL OF BYPASSED SENSORS
Bypassed sensors are ignored by the Control
Panel and cannot cause an alarm.
The factory setting causes the Control Panel to
automatically restore (remove the bypass from)
sensors that close. After it's restored, the sensor is
ready to cause an alarm the next time it is opened.
STEP #66 The Control Panel can be programmed to not
automatically restore any bypassed sensor when
the sensor closes using this step. Bypassed
sensors will then remain bypassed until the
system is disarmed.
NOTE: This setting affects all sensors.
AUTOMATIC BYPASSING OF OPEN SENSORS
The factory setting requires the user to manually
bypass any open sensors when the system is
armed.
If arming is attempted with open sensors, the keypad(s)
will sound fi ve two-tone Beeps and will not arm.
Arming to the same mode again within fi ve
seconds will bypass any open sensors and arm
the Control Panel.
STEP #67 The Control Panel can be programmed to
automatically bypass any open sensors when the
system is armed using this step.
NOTE: This setting affects all sensors.
PROGRAMMING
STEP #63
PROGRAM
0 FOR AUDIBLE BURGLARY
1
FOR SILENT BURGLARY
STORE - 1 BING
PROGRAMMING
STEP #64
ENTERS STEP NUMBER
0 FOR AUDIBLE EMERGENCY
1
FOR SILENT EMERGENCY
STORES VALUE - 1 BING
PROGRAMMING STEP #66
ENTERS STEP NUMBER
0 FOR AUTO RESTORAL OFF
1
FOR AUTO RESTORAL ON
STORES VALUE - 1 BING
PROGRAMMING STEP #65
ENTERS STEP NUMBER
0 FOR QUICK ARMING OFF
1
FOR QUICK ARMING ON
STORES VALUE - 1 BING
PROGRAMMING STEP #67
ENTERS STEP NUMBER
0 FOR AUTO BYPASS OFF
1
FOR AUTO BYPASS ON
STORES VALUE - 1 BING