Linear DUAL 824 Home Security System User Manual


 
5
HARDWIRED KEYPAD
One or two hardwired keypads can be used for
controlling the system.
Three system status indicators:
READY, ARMED, & TROUBLE
Three system supervisory indicators:
POWER, BATTERIES, & RADIO
Five system mode indicators:
OFF, CHIME, HOME, AWAY & TEST
24 system sensor indicators.
Location inside beauty cover for supplied sensor
identifi cation labels.
Press
to activate the automation output.
Pressing
clears the keypad.
Pressing
for two seconds sounds the mode
Beeps from the hardwired keypad(s).
Off Mode: 1 “Gong”.
Chime Mode: 1 “Gong” & 1 “Beep”.
Home Mode: 1 “Gong” & 2 “Beeps”.
Away Mode: 1 “Gong” & 3 “Beeps”.
Test Mode: 1 “Gong” & 4 “Beeps”.
Emergency and fi re alarm can be triggered from
the keypad at any time.
UL NOTE: For personal emergency use only. Not
for use as a UL Listed Medical Alert System.
WIRELESS KEYPAD
For controlling the system remotely.
Green operation light.
Internal 9-volt battery is monitored by the Control
Panel.
Keypad's beeper will buzz during transmissions
when the battery is low.
Up to 3 years battery life (depends on frequency
of activation). (UL tested for 1 year minimum.)
Sends hourly status reports to the Control Panel.
Press to activate the automation output.
Pressing clears the keypad.
Pressing for two seconds sounds the mode
Beeps from the hardwired keypad(s).
Off Mode: 1 “Gong”.
Chime Mode: 1 “Gong” & 1 “Beep”.
Home Mode: 1 “Gong” & 2 “Beeps”.
Away Mode: 1 “Gong” & 3 “Beeps”.
Test Mode: 1 “Gong” & 4 “Beeps”.
Emergency and fi re alarm can be triggered from
the wireless keypad at any time.
UL NOTE: For personal emergency use only. Not
for use as a UL Listed Medical Alert System.
ABOUT SENSOR STATUS SUPERVISION
All DXS Format sensors transmit hourly status reports. All DXT
Format sensors do not transmit hourly status reports. Both sensor
formats can be used with the system.
When a sensor is programmed into the Control Panel, the system
will set the sensor as non-supervised or supervised. Sensors set
as non-supervised are not expected to send hourly status reports.
Sensors set as supervised are expected to send hourly status
reports. If a status report is not received in 8 hours from a sensor
set as supervised, the RADIO indicator will fl ash.
When sensors are programmed into the Control Panel, ALL
STATIONARY SENSORS ARE SET AS SUPERVISED, ALL
PORTABLE SENSORS ARE SET AS NON-SUPERVISED.
If stationary DXT Format sensors have been programmed into the
Control Panel, be sure to change their setting to non-supervised
to prevent RADIO indications. This will not prevent low battery
monitoring.
If portable DXS Format sensors have been programmed into the
Control Panel, and the installation requires supervision for specifi c
portable sensor(s), change the selected portable sensors setting to
supervised.
After programming the sensors, if changes are required, refer to
“Changing a Sensors Supervision” on Page 30 for details on
changing the way a sensor’s supervision is set.
3. OVERVIEW OF KEYPADS
HARDWIRED
KEYPAD
WIRELESS
KEYPAD