Linear DUAL 824 Home Security System User Manual


 
15
PROGRAM THE HARDWIRED LOOPS
Each hardwired loop used must be programmed
into the Control Panel's memory.
Each hardwired loop programmed uses one of
the twenty four available sensor locations.
1. Start with the system in Test Mode (enter the
master user code and press TEST).
2. Enter the Setup Mode from Test Mode, enter the
master user code then press TEST again.
A “Gong” and fi ve “Beeps” will sound. The system is now
in Setup Mode.
The sensor status indicators will light for any sensors
already programmed into the Control Panel.
3. Enter programming Step #301-308 (301=loop 1,
302=loop 2, etc.) for the hardwired loop desired.
4. Press HOME to select step.
5. Enter an unused sensor number from 01-24 for
the loop (you must enter two digits, example:
5 = 05).
6. Press AWAY to store.
A single “Bing” tone will sound and the sensor status
indicator for that sensor will stay lit. A double “Buzz” will
sound if that sensor location is already in use.
7. Repeat Steps 3-6 to enable all of the hardwired
loops used.
NOTE: The default sensor function for the
hardwired loops is Perimeter (Type 5). Any sensor
function can be selected for each hardwired loop,
refer to the “Customizing the System” section of
this manual.
PROGRAM THE WIRELESS SENSORS
Each wireless sensor used must be programmed
into the system’s memory. See the next two pages for
details on activating different models of transmitters.
Each wireless sensor programmed uses one of
the twenty four available sensor locations.
1. Start with the system in Test Mode (enter any
user code and press TEST).
2. Enter the Setup Mode from Test Mode, enter the
master user code then press TEST again.
A “Gong” and fi ve “Beeps” will sound. The system is now
in Setup Mode.
The sensor status indicators will light for any sensors
programmed into the Control Panel.
3. Enter an unused sensor number from 01-24 (you
must enter two digits, example: 5 = 05).
The sensor indicator light will fl ash for the sensor number
selected.
4. Activate the sensor by sending a test or alarm
signal (be sure the sensor's battery is connected
or that its battery protection strip is removed).
A single “Bing” tone will sound and the sensor status
indicator for that sensor will stay lit. A “Buzz” will sound if
that sensor location is already in use.
5. Repeat Steps 3 & 4 for each additional sensor, or
exit Setup Mode by pressing the OFF button for
three seconds.
START IN TEST
MASTER
USER
CODE
1 GONG & 5 BEEPS
(SETUP MODE)
STEP #301-308
FOR LOOP #1-8
ENTERS STEP
NUMBER
STORES LOOP
SENSOR NUMBER
1 BING
SENSOR
NUMBER (01-24)
FOR LOOP
DONE
START IN TEST
MASTER
USER
CODE
1 GONG & 5 BEEPS
(SETUP MODE)
NEW SENSOR
NUMBER
1 BING AND
SENSOR
INDICATOR
LIGHTS
REPEAT OR EXIT
ACTIVATE
SENSOR
SENSOR
INDICATOR
FLASHES