Chapter 9 List of Error Codes
E-02
E-03
E-04
E-05
E-06
E-07
E-09
E-0A
E-14
E-18
E-21
E-22
E-23
E-24
E-25
E-26
E-27
E-28
E-29
E-2A
E-2B
E-2C
E-2D
E-2E
E-2F
Turn the power off once, then on again. If the same
error occurs again, the area sensor is faulty.
Press
STOP
and clear the error message. Pressing
START
restarts the home position detecting movement again.
Turn the power off once, then on again. If the same error
occurs again, the X- or Y-axis mechanism is faulty.
Adjust the pulley stop position (100°) above the needle
and press
STOP
.
Press
STOP
. If the error persists, the color-change
mechanism is faulty.
Turn the power off once, then on again. If the same
error occurs again, the X-axis mechanism is faulty.
After passing through the thread, press
STOP
.
Turn the power off once, then on again. If the same
error occurs again, the Y-axis mechanism is faulty.
Check that the connector of the X-axis stepping motor
is properly connected, and press
STOP
.
Set the embroidering area again or move the hoop to a
sewable position. (The hoop can be moved to a
sewable position by pressing .)
Code Error Measures
Overtravel error during home
positioning detection
Stop SW was pressed during home
positioning
Zero positioning is out of range
Needle stop position error
Needle bar case position error
Needle bar case lock
X-axis home position error
Thread breakage error
Y-axis home position error
X-axis stepping motor connector error
Area over