Baldor BXII Home Security System User Manual


 
Operation 5-15MN1904
4. In the Move Type drop down box, check that
the move type is set to S tep.
5. Click in the Distance box and enter a d istance
for the step move. It is recommended to set a
value that will cause the motor to turn a short
distance, for example one revolution.
Note:
The distance depends on the scale set in
section 5.3.1. If you set a scale so that units could be expressed in revolutions (or other unit
of your choice), then those a re the units that will be used here. I f you did not set a scale, the
amount you enter will be in encoder quadrature counts.
6. Click in the Duration box and enter a duration
for the move, in seconds. This should be a
short duration, for example 0.15 seconds.
7. Click Go.
The NextMove BX
II
will perform the move and the motor will turn. As the soon as the move is
completed, WorkBench v5 will download captured data from the NextMove BX
II
. The data will
then be displayed in the Capture window as a graph.
Note: The graphs that you see will not look exactly the same as the graphs shown here!
Remember that each motor has a slightly different response.
8. Using the check boxes below the g raph, select
the traces you require, for example Demand
position and Measured position.