The inputs are conditioned using Schmitt trigger buffers. If an input is configured as edge
triggered, the triggering pulse must have a duration of at least 1ms (one software scan) to
guarantee acceptance by Mint. The use of shielded cable for inputs is recommended.
Active high: connect +24VDC to the input and 0V to pin 9 (CREF).
The digital inputs will be active when a voltage of +24VDC (greater than 12VDC) is applied to
them and will sink a current of approximately 11mA each.
Active low: connect +24VDC to pin 9 (CREF) and 0V to the input.
The digital inputs will be active when grounded (<2V) and will source a maximum of 11mA
each.
Note: Sustained input voltages above 28V will damage the inputs.
4.6.2 Digital inputs - X2
Location Connector X2
(Mating connector: Weidmüller BL 3.5/10, 3.5mm pitch)
Pin Name Mint keyword / description
1 DIN0 INX.0
2 DIN1 INX.1
3 DIN2 INX.2
4 DIN3 INX.3
5 DIN4 INX.4
6 DIN5 INX.5
7 DIN6 INX.6
8 DIN7 INX.7
9 Common Common connection
10 Shield Shield connection
Description
Eight general purpose optically isolated AC digital inputs.
Sampling interval: 1ms
The inputs are electrically identical to inputs DIN8 to DIN15 described in section 4.6.1.