28
Toshiba
6-3. Hot Water Cylinder Unit
O·········Applied
No. Component name
Model name
Type name Rating
1501
CSH
M3-E
(-UK)
2101
CSH
M3-E
(-UK)
3001
CSH
M3-E
(-UK)
1
Hot water cylinder heater
OOO
AC230 V 2.75 KW
2
Hot water cylinder temperature
sensor
(TTW sensor)
OOO
10 kΩ (25°C)
3
Thermal cut-out
OOO
Operating temperature
Manual reset 82°C (+3k/-2k)
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 28 Monday, October 5, 2009 2:09 PM