StorageTek 312564001 Water System User Manual


 
164 DB2 Manager User Guide
StorageTek Proprietary
OTD26007 Tape wtr task nnn abend Sxxx intercepted
Explanation: A system abend has been intercepted during operation of tape writer
task ‘nnn’. The system abend code is 'xxx'. Tape writer processing
will continue.
Action: A system abend has been trapped during processing of a migrated
row storage request. If possible, DB2 Manager will recover from the
abend.
If it is not possible for DB2 Manager to recover from the abend, the
tape writer task will be terminated abnormally.
The problem should be reported to your DB2 Manager product
support representative.
OTD26009 Tape wtr task nnn terminated
Explanation: Tape writer task number ‘nnn’ has terminated processing in response
to an operator command, or following an unrecoverable error
condition.
Action: None. This is an informational message.
OTD26011 Return code xx Supp codes X'yyyyzzzz' received opening | updating
| committing | closing d/b dddd, T=Wnnn
Explanation: An error has been received by tape writer task ‘nnn’ accessing the
Archive Manager database with identifier ‘dddd’, for the type of
processing identified in the message. ‘xx’ gives the return code
received from the Archive Manager call, and ‘yyyy’ and ‘zzzz’ give
supplementary error codes 1 and 2. Processing of the current request
is terminated with an error.
Action: Refer to the Archive Manager User Manual for an explanation of the
return and supplementary codes displayed in the message. Take the
appropriate corrective action and re-start the row migration job.
OTD26012 Unrecoverable error condition – tape writer task nnn terminating
Explanation: An error condition has been encountered during processing of a
request by tape writer task ‘nnn’, and the task is unable to recover.
The request will be terminated with an error condition and the writer
task will terminate. The value of the MAXTWTR initialization
parameter will be automatically decremented by 1.
Action: Examine the system log for other DB2 Manager messages giving
information about the original error condition. Take the appropriate
corrective action and re-start the row migration job. To restart the
terminated writer task, set the value of MAXTWTR to its value prior to
termination of the task.