OTD17013 Retrieval using the specified KEY fields cannot be made via
INDEXONLY processing
Explanation: Scanning of the table using the key fields specified in the SELECT
statement in the SQLIN file cannot be performed via index-only
processing. Execution of the utility cannot continue, and is
terminated with a condition code 12.
Action: Modify the SELECT statement in the SQLIN file to ensure that the
specified columns are those used to uniquely index a row in the table,
and re-submit the job.
OTD17014 Return Code xx, Supp codes X'yyyyyyyy' received during OPEN |
QUERY | DELETE | CLOSE processing for Archive Manager
database zzzz
Explanation: An error has been received from an Archive Manager open, query,
delete or close request. ‘xx’ gives the return code and ‘yyyyyyyy’ the
hexadecimal supplementary reason codes received from Archive
Manager. Execution of the utility has been terminated with condition
code 12.
Action: Refer to the Archive Manager User Manual for a description of the
return and supplementary codes displayed in the message. Take the
appropriate corrective action and re-submit the job. If no obvious
reason for the error can be identified, contact your local STK support
representative.
OTD200xx – control region master processor
messages
Messages from the DB2 Manager control region master processor are written to the
system log.
OTD20000 Enter request:
Explanation: This is the operator reply message displayed by the control region
after successful initialization.
Action: All DB2 Manager operator commands are entered as responses to
this message. After processing a command, the control region will
redisplay this message.
OTD20001 Error opening parameter file SYSPARM
Explanation: An error has occurred opening the DB2 Manager parameter library
during initialization processing. Initialization is terminated.