136 DB2 Manager User Guide
StorageTek Proprietary
Action: Check that the correct DB2 table name has been specified in the
SQLIN file. If not, correct the entry and re-submit the job.
OTD14012 All columns in the DB2 table have been specified as KEY fields
Explanation: There are no non-indexed columns in the table being analyzed. The
utility requires that there be at least one non-index column in the
table. Processing of the utility is terminated with condition code 12.
Action: Check that the correct table name has been specified in the SQLIN
statement. If it has, and the table contains no non-index columns,
then the utility cannot be executed against this table.
OTD14013 Retrieval using the specified KEY fields cannot be made via
INDEXONLY processing
Explanation: Scanning of the table using the key fields specified in the SELECT
statement in the SQLIN file cannot be performed via index-only
processing. Execution of the utility cannot continue, and is
terminated with a condition code 12.
Action: Modify the SELECT statement in the SQLIN file to ensure that the
specified columns are those used to uniquely index a row in the table,
and re-submit the job.
OTD14014 Return Code xx, Supp codes X'yyyyyyyy' received during OPEN |
QUERY | CLOSE processing for Archive Manager database zzzz
Explanation: An error has been received from an Archive Manager open, query or
close request. ‘xx’ gives the return code and ‘yyyyyyyy’ the
hexadecimal supplementary reason codes received from Archive
Manager. Execution of the utility has been terminated with condition
code 12.
Action: Refer to the Archive Manager User Manual for a description of the
return and supplementary codes displayed in the message. Take the
appropriate corrective action and re-submit the job. If no obvious
reason for the error can be identified, contact your local STK support
representative.