114 DB2 Manager User Guide
StorageTek Proprietary
4 - a warning condition has been encountered during processing
of the utility. A warning message will have been written to the
SYSPRINT dataset. The utility has been executed
successfully.
8 - an error condition has been encountered during processing of
the utility. An error message will have been written to the
SYSPRINT dataset. Execution of the utility has continued.
12 - a serious error has been encountered during processing of the
utility. An error message will have been written to the
SYSPRINT dataset. Execution of the utility has been
terminated.
Utility failure and restart considerations
If the database housekeeping utility fails to complete successfully (return
code greater than 8), consult the error report in the SYSPRINT dataset to
identify the cause of the problem. Refer to chapter 7 for a description of the
message(s) appearing in the error report.
All deletes of Archive Manager objects completed up to the point of failure will
be committed in the Archive Manager database. All DB2 updates performed
for normalization of archive stub storage will be rolled back. DB2 updates are
only committed on successful completion of the utility.
After correcting the error, the utility may be rerun normally. The utility will
start housekeeping processing from the beginning of the table once again.
No special actions need to be taken prior to re-starting the failed database
housekeeping job.
Archive Manager database maintenance
Following successful completion of the DB2 Manager database
housekeeping utility, the Archive Manager database used for storage of
migrated rows from the processed DB2 table will contain one or more deleted
objects. In order to recover the index and tape and disk storage space
occupied by deleted objects, the Archive Manager database maintenance
procedure must be performed. Maintenance of an Archive Manager
database is performed by executing the following Archive Manager utilities:
• OTASP040 – the object management utility. This will recover the
index entries for deleted objects and update tape residency statistics
to allow tape recycling to take place.
• OTASP030 – the database maintenance utility. This will recycle data
from all tape volumes in one or more storage levels of an Archive
Manager database whose level of active objects falls below a user-
defined threshold.
Refer to the Archive Manager User Manual for a full description of this utility
and of its use in the Archive Manager database maintenance procedure.