StorageTek 312564001 Water System User Manual


 
102 DB2 Manager User Guide
StorageTek Proprietary
This mandatory parameter is used to specify the subsystem identifier of
the DB2 subsystem to be used during execution of the utility. The
subsystem identifier ‘xxxx’ can be 1-4 characters in length.
PLAN=xxxxxxxx
This is an optional parameter which is used to specify the DB2 plan name
to be used during execution of the utility, where ‘xxxxxxxx’ is the 1-8
character identifier of the plan. If omitted, a default value of OTDBL130 is
used. Refer to “Perform DB2 system modifications” on page 25 for
information about DB2 Manager plan creation processing.
BATCH = nnnnn|0
This is an optional parameter used to specify the maximum number of
pre-fetch requests which are to be processed by Archive Manager in a
single batch. ‘nnnnn’ is a 1-5 digit numeric value in the range 0-99999,
specifying the number of requests to be processed per batch. A value of
0 indicates that there is no maximum to the size of the request batch – all
rows identified for pre-fetching during execution of the utility will be
processed in a single batch. If this parameter is omitted, a default value
of 0 is used.
INDEXONLY=Y
|N
This optional parameter is used to control whether the selection criteria
specified by the user for pre-fetching rows are to be capable of resolution
via table indexes only. The default value of “Y” indicates that the
selection criteria must be capable of resolution via indexes only. If this is
not the case, the program will issue an error message and terminate with
a condition code 12. A value of “N” indicates that the selection criteria do
not need to be capable of resolution via indexes only. In this case,
execution of the pre-fetch job may cause the utility to sequentially process
all migrated rows from the Archive Manager database.
If this parameter is omitted, the default value of “Y” is used.
PRINT=DETAIL|SUMMARY
This is an optional parameter which is used to control the level of
reporting performed by the utility. If a value of SUMMARY is specified for
this parameter, the detailed processing report will be omitted. All other
print reports will be produced as normal. If the default value of DETAIL is
specified, all print reports (including the detailed processing report) will be
produced.
SQLIN entry specification
The SQLIN file is a fixed-block sequential dataset with a logical record length
of 80 bytes. It must contain one or more records containing a free-format text
description of the rule(s) to be used for selection of rows to be pre-fetched by
Archive Manager. Character positions 1-71 will be used for this description.