Pelco ES30TI Home Security System User Manual


 
54 C1307M-C (8/07)
Appendix
NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the
DIP switch settings have no effect on Coaxitron control signals.
*SW1-3 is not used; set it in the OFF position.
*SW1-4 is not used; set it in the OFF position.
Table A. Switch Settings for SW1
Switch Setting
Baud Rate SW1-1 SW1-2 SW1-3
2400 OFF OFF OFF*
4800 ON OFF OFF*
9600 OFF ON OFF*
Table B. Switch Settings for SW2
Switch Setting
SW1-4 SW1-5 SW1-6 SW1-7 SW1-8
OFF* Note (1) Note (2) Note (3) Note (4)
NOTES:
(1) SW1-5 OFF For controllers with more than 32 presets.
ON For American Dynamics controllers (32 presets).
(2) SW1-6 OFF For all control systems except CM9502 with variable speed keyboards. For CM9502
with fixed speed keyboards, set to OFF.
ON For CM9502 with variable speed keyboards for smoother joystick control.
(3) SW1-7 OFF RS-422 transmitter is not terminated.
ON RS-422 transmitter is terminated.
(4) SW1-8 OFF 1.2 Vp-p video level.
ON 1.0 Vp-p video level.