Napco Security Technologies GEM-P3200 Home Security System User Manual


 
X GEM-P3200 Programming Instructions
L NAPCO Security Systems
Page 32
WI818G 10/05
ZONE OPTIONS / ZONES 33-48 (ADDRESS 1602-1786)
ZONE OPTIONS / ZONES 33-48
ZONES 33 40
ZONES 41 48
ZONE OPTIONS ADDR Z33 Z34 Z35 Z36 Z37 Z38 Z39 Z40 ADDR Z41 Z42 Z43 Z44 Z45 Z46 Z47 Z48
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Priority 1602 1702
Priority with Bypass 1603 1703
Auto-Bypass 1604 1704
Selective Bypass 1605 1705
Keyswitch Arming 1606 1706
Auto-Bypass Re-entry 1607 1707
Pre-Alarm Warning 1608 1708
Never Arm 1609 1709
24-Hour Zone 1610 1710
Burg. Alarm Output 1611 1711
Pulsed Alarm Output 1612 1712
Fire Output (Lug E9) 1613 1713
Reset Relay 1614 1714
Auxiliary Relay 1615 1715
Entry/Exit 1 1616 1716
Entry/Exit 2 1617 1717
Exit/Entry Follower 1618 1718
Auto Reset 1619 1719
Swinger Shutdown 1620 1720
Chime 1621 1721
Abort Delay 1622 1722
Power-up Delay 1623 1723
Day Zone Open 1624 1724
Day Zone Short 1625 1725
Alarm on Day Zone 1626 1726
RPT Alarm Tel 1 1627 1727
RPT Alarm Restore Tel 1 1628 1728
RPT Trouble Tel 1 1629 1729
RPT Trouble Restore Tel 1 1630 1730
RPT Alarm Tel 3 1635 1735
RPT Alarm Restore Tel 3 1636 1736
RPT Trouble Tel 3 1637 1737
RPT Trouble Restore Tel 3 1638 1738
No EOL Resistor 1639 1739
Sensor Watch 1640 1740
Trouble on Open 1641 1741
Trouble on Short 1642 1742
Trouble on Night Open 1643 1743
Zone Area 1 1644 1744
Zone Area 2 1645 1745
RESERVED 1653
1753
Zone ANDing Group 1 1654
1754
Zone ANDing Group 2 1655
1755
Interior #1 Bypass 1662 1762
Interior #2 Bypass 1663 1763
Keypad Sounder on Alarm 1664
1764
Fire (C) 1675 1775
Fire Alarm Verification (C) 1676
1776
Interior (STAY) Bypass 1684
1784
Chime 2
1686 1786
When the Easy Program Menu is used, these features are enabled by default (for new panels or after a Cold Start (address 4093)).
Do not program if "K Series" keypads (with "
P" and "Q" buttons) are used in the system.
Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
In UL installations, all Fire Zones must also be programmed for "Pulse Burg Output Cadence" (Address 2422, press 1 (bit zero)).
See Zone Options on Page 33.