RF RECEIVERS & SUPERVISORY TIMER OPTIONS (ADDRESS 3776 & 3760-3775)
RF RECEIVERS: Up to 2 RF Receivers may be programmed. NOTE: This
adds wireless capability to the system, increasing up to 48 the number of zones.
1. Select the number of receivers (1-2).
2. Enter the corresponding decimal number (1-2) into the right-most loca-
tion. Press U or D to save.
RF RECEIVERS & SUPERVISORY TIMER OPTIONS
DATA
ENTRIES
RF
RECEIVER(S)
0 None
1 1
2 2
Default Number of Receivers = 0
Number of RF
Receivers
0 0
ADDRESS 3776
LEFT RIGHT
blank (•) blank (•)
blank (•) 1
blank (•) 2
blank (•) 3
blank (•) 4
blank (•) 5
blank (•) 6
blank (•) 7
blank (•) 8
blank (•) 9
blank (•) 0
blank (•) B
blank (•) C
blank (•) D
blank (•) E
blank (•) F
1 blank (•)
1 1
1 2
1 3
1 4
1 5
1 6
1 7
1 8
1 9
1 0
1 B
1 C
1 D
1 E
1 F
2 blank (•)
2 1
2 2
2 3
2 4
2 5
DATA ENTRIES
DELAY
0 min.
10 min.
20 min.
30 min.
40 min.
50 min.
60 min.
70 min.
80 min.
90 min.
100 min.
110 min.
120 min.
130 min.
140 min.
150 min.
160 min.
170 min.
180 min.
190 min.
200 min.
210 min.
220 min.
230 min.
240 min.
250 min.
260 min.
270 min.
280 min.
290 min.
300 min.
310 min.
320 min.
330 min.
340 min.
350 min.
360 min.
370 min.
RF SUPERVISORY TIMERS
LEFT RIGHT
2 6
2 7
2 8
2 9
2 0
2 B
2 C
2 D
2 E
2 F
3 blank (•)
3 1
3 2
3 3
3 4
3 5
3 6
3 7
3 8
3 9
3 0
3 B
3 C
3 D
3 E
3 F
4 blank (•)
4 1
4 2
4 3
4 4
4 5
4 6
F F
DATA ENTRIES
DELAY
380min.
390 min.
400 min.
410 min.
420 min.
430 min.
440 min.
450 min.
460 min.
470 min.
480 min.
490 min.
500 min.
510 min.
520 min.
530 min.
540 min.
550 min.
560 min.
570 min.
580 min.
590 min.
600 min.
610 min.
620 min.
630 min.
640 min.
650 min.
660 min.
670 min.
680 min.
690 min.
700 min.
2550 min. = 42
Hr., 30 min.
RF SUPERVISORY TIMERS
RF SUPERVISORY TIMERS: RF Supervisory Timers may be
programmed for each type of transmitter used. A transmitter will
send a transmission every time it is tripped, when there is NO
activity, the transmitter sends a status transmission about once
an hour. If the receiver does NOT receive ANY signal (a trip or a
status) from a transmitter in the time specified for transmitter
type, a system trouble “
E-04-NN” will be displayed at the keypad.
1. Select timer delay from the table shown. Timers are
programmed in increments of 10 minutes each. Valid
entries are (•)8-FF (80 minutes-2550 min) (2550 minutes =
42 hr,30 min).
WARNING: Timers have uncertainty of +/-30 minutes.
2. Enter in corresponding address locations above (left
and right digits).
3. For a desired timer not listed do the following:
A. Choose a desired timer (intervals of 10),
ex: 1440 min. (24 Hours)
B. Divide it by 10, ex: 1440/10 = 144
C. Divide it by 16
6 Quotient Left Digit
16 100
96
4 Remainder Right Digit
NOTE: These timers apply only to Supervised RF
Transmitters (see RF Transmitters in Easy Menu Driven Mode
Programming).
[Default = blank (•) 8 from address 3760-3767 (80 minutes)]
LEFT ADDR RIGHT
3760
3761
3762
3763
3764
3765
3766
3767
ADDRESS
3760-3767
RF SUPERVISORY
TIMER
RF TRANSMITTER
Type 0 Window/Door, 2 Pt.
Type 1 Window/Door, 2 Pt.
Type 2 Window/Door, 2 Pt.
Type 3 Window/Door, 2 Pt.
Type 4 Window/Door, 4 Pt.
Type 5 PIR
Type 6 PIR
Type 7 Smoke Detector
[Default = blank (•) 8 from address 3768-3775 (80 minutes)]
LEFT ADDR RIGHT
3768
3769
3770
3771
3772
3773
3774
3775
ADDRESS
3768-3775
RF SUPERVISORY
TIMER
RF TRANSMITTER
Type 8 Smoke Detector
Type 9 Keyfob
Type A Dual Tech.
Type B Keyfob
Type C Window/Door, 4 Pt.
Type D PIR
Type E Smoke Detector
Type F Napco Glass Break