A 4-digit Compatibility Number, if programmed, will restrict this keypad to
work on a panel programmed with a matching number.
1. Enter a 4-digit number
2. Press
U to save. Press the R button to continue or press the
C button to exit.
EZM Address
The keypad's internal EZM (Expansion Zone Module) may be utilized to
provide four additional wired zones. Whether used alone or in conjunction
with optional GEM-EZM series modules or other keypad EZMs, it must be
assigned a unique address (or Group number, see Keypad Programming
Workbook) similar to its keypad address. If no other EZMs are to be used, designate the keypad as Group “01” at the
EZM ADDRESS 00” display. In multiple-EZM systems, enter an assigned group number “01” through “06”. (Each
EZM must have a unique assigned group number, starting with “01” and proceeding consecutively.) Press the
R
button to continue or press the
C button to exit.
Zone Response
The normal loop response of each keypad expansion zone is 750mS, how-
ever the response time of any zone can be reduced to 50mS as follows.
1. Of the following, circle the number(s) in parentheses associated with the
zone(s) to be changed: Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8)
2. Add up the circled numbers.
3. At the keypad, enter the sum as a two-digit number “01” through “15” on the display, then press
U.
Example. Change Zones 2, 3 and 4 to 50mS response.
1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8).
2. Add up the circled numbers: 2 + 4 + 8 = 14.
3. Enter “14” at the keypad, then press the
U button.
Press the
R button to continue or press the C button to exit.
Program Control Message
A code-keypad association can be programmed such that when the code is
entered at a specific keypad, a PGM Lug will be activated for 7 seconds,
and a selected message will be displayed on this keypad. Six different pro-
gram control messages can be selected (0-6) as displayed in the following table:
1. Enter a message number
2. Press U to save.
3. Press the
R button to continue (the display will loop back through selections, for changes) or press the
C button to exit the Keypad Configuration Mode (display will read “01 OUT OF SYSTEM”).
4. Replace Jumper JP1 across Pins 1–2 (top two).
New
Compat # 0000
EZM Address
01
Zone Response
00
Program Control
Message # ?
0 (No Message)
1 **Enter Now**
2 Door Control
3 Gate Control
4 Light Control
5 Control #1
6 Control #2
Program Control Message