Napco Security Technologies GEM-P3200 Home Security System User Manual


 
THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN CONTROL PANEL FIRMWARE
VERSION 50 OR LATER.
IMPORTANT NOTE
This manual supports the keypad programming of the GEM-P3200 control panel with the NAPCO "classic" GEM-
RP1CAe2 keypad as well as the GEM-K1CA "K Series" keypad. The new "K Series" GEM-K1CA model offers the new
STAY and AWAY buttons with simplified functionality, along with the new MENU and ENTER buttons. Note: While the
instructions in this manual are depicted using the GEM-K1CA keypad, the manual applies to both the "classic" and the
"K Series" keypads.
Program Mode is the same for both keypads--only the button names have changed, as follows:
The A button and the R button operate identically (in Program Mode) for both keypads.
The D button and the U button operate identically (in Program Mode) for both keypads.
The
button and the button operate identically (in Program Mode) for both keypads. The words
"NEXT/YES button" are used in this manual.
The
button and the button operate identically (in Program Mode) for both keypads. The words
"PRIOR/NO button" are used in this manual.
For consistency, it is recommended that all keypads either be all "classic" or all "K Series"--both keypad
types should not be used in one alarm system.
NAPCO Security Group, Inc.,
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, call toll free: (800) 645-9445
For direct line to Technical Service, call toll free: (800) 645-9440
Internet: http://www.napcosecurity.com
CHANGES FROM PREVIOUS EDITION
The following changes have been made to this manual (WI818G) since the previous edition (WI818F).
New addresses added to accommodate the GEM-ACM1D / GEM-2D Access Control Accessories, as follows:
Enable ACM Access
ACM Zone Options
ACM Global Flags
ACM Timeouts
ACM Door Area Options
ACM Scheduled Free Access
Enable Panel Options
Emergency Free Access
Keypad Home Area / ACM Door #1 Area (Hex)
Addition to the Easy Program Menu instructions, "Enter Proximity Card Users".
Existing addresses were changed and new addresses were added to accommodate the NAPCO NetLink™ NL-Mod device, as follows:
For each telephone number desired, enable "Report to TCP/IP Receiver or AES" for Telco 1, Telco 2 and Telco 3.
Enable "Callback Telephone No. Select". Enter either "1" for Callback Telephone Number 1 or "2" for Callback Telephone Number 2.
Enable "Handshake for Local Telemetry"
Enable "TCP/IP Communications"
Enable "TCP/IP Panel/Site Initiated Functions"