Napco Security Technologies GEM-P3200 Home Security System User Manual


 
L NAPCO Security Systems
X GEM-P3200 Programming Instructions
Page 31
WI818G 10/05
ZONE OPTIONS / ZONES 17-32 (ADDRESS 1402-1586)
ZONE OPTIONS / ZONES 17-32
ZONES 17 24 ZONES 25 32
ZONE OPTIONS ADDR Z17 Z18 Z19 Z20 Z21 Z22 Z23 Z24 ADDR Z25 Z26 Z27 Z28 Z29 Z30 Z31 Z32
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Priority 1402 1502
Priority with Bypass 1403 1503
Auto-Bypass 1404 1504
Selective Bypass 1405 1505
Keyswitch Arming 1406 1506
Auto-Bypass Re-entry 1407 1507
Pre-Alarm Warning 1408 1508
Never Arm 1409 1509
24-Hour Zone 1410 1510
Burg. Alarm Output 1411 1511
Pulsed Alarm Output 1412 1512
Fire Output (Lug E9) 1413 1513
Reset Relay 1414 1514
Auxiliary Relay 1415 1515
Entry/Exit 1 1416 1516
Entry/Exit 2 1417 1517
Exit/Entry Follower 1418 1518
Auto Reset 1419 1519
Swinger Shutdown 1420 1520
Chime 1421 1521
Abort Delay 1422 1522
Power-up Delay 1423 1523
Day Zone Open 1424 1524
Day Zone Short 1425 1525
Alarm on Day Zone 1426 1526
RPT Alarm Tel 1 1427 1527
RPT Alarm Restore Tel 1 1428 1528
RPT Trouble Tel 1 1429 1529
RPT Trouble Restore Tel 1 1430 1530
RPT Alarm Tel 3 1435 1535
RPT Alarm Restore Tel 3 1436 1536
RPT Trouble Tel 3 1437 1537
RPT Trouble Restore Tel 3 1438 1538
No EOL Resistor 1439 1539
Sensor Watch 1440 1540
Trouble on Open 1441 1541
Trouble on Short 1442 1542
Trouble on Night Open 1443 1543
Zone Area 1 1444 1544
Zone Area 2 1445 1545
RESERVED 1453
1553
Zone ANDing Group 1 1454
1554
Zone ANDing Group 2 1455
1555
Interior #1 Bypass 1462 1562
Interior #2 Bypass 1463 1563
Keypad Sounder on Alarm 1464
1564
Fire (C) 1475 1575
Fire Alarm Verification (C) 1476
1576
Interior (STAY) Bypass 1484
1584
Chime 2
1486 1586
When the Easy Program Menu is used, these features are enabled by default (for new panels or after a Cold Start (address 4093)).
Do not program if "K Series" keypads (with "
P" and "Q" buttons) are used in the system.
Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
In UL installations, all Fire Zones must also be programmed for "Pulse Burg Output Cadence" (Address 2422, press 1 (bit zero)).
See Zone Options on Page 33.