EZM GROUP OPTIONS (ADDRESS 2555-2576)
Default depends on Easy Menu questions:
"# OF ZNS IN AREA1"
and
"# OF ZNS IN AREA2"
For example, If 32 zones are used, then all 6 groups will be automatically enabled.
If only 8 zones are used, then groups 1-6 will be automatically disabled.
ADDRESS 2555
EZM Group 1
ZONES 9-12
ADDRESS 2556
EZM Group 2
ZONES 13-16
ADDRESS 2557
EZM Group 3
ZONES 17-20
ADDRESS 2558
EZM Group 4
ZONES 21-24
ADDRESS 2559
EZM Group 5
ZONES 25-28
ADDRESS 2560
EZM Group 6
ZONES 29-32
NOTE: Zones 1-8 are included in the control panel and Zones 9-32 (Groups 1-6) are EZM Zones (either Wireless or
Hardwired). Zones 33-48 are wireless only.
EZM TYPE
DATA
ENTRIES
RIGHT
OPTION
blank (•) Not used (No
EZM present)
1 4-Zone EZM
EZM GROUP OPTIONS: Up to 6 Groups of 4 Zones each may be programmed depending on the
number of zones used and which EZM modules are connected. Each group represents 4 zones.
1. Select EZM type from the table shown.
2. Enter either blank (•) or "1" in corresponding address locations above.
3. Press U or D to save
EZM PGM ARMED TERMINAL CONTROL: For each zone group select the area(s) which, when armed, will activate the PGM Lug
on the corresponding EZM modules. Each zone group corresponds to 4 zones. If 8-Zone EZMs are used, each one is treated as
TWO zone groups. NOTE: Lug goes ACTIVE (low) when EITHER selected area is armed. When activated, the PGM Lug goes
negative (to ground).
1. Select the desired group number.
2. Enter the corresponding Area number in each the address location, in Binary (Bit) Format. NOTE: See Direct Address
Programming Example on page 15.
3. Press U or D to save.
EZM GROUP OPTIONS
GROUP
NUMBER
EZM PGM TERMINAL CONTROL
ADDR A1 A2 A3 A4 A5 A6 A7 A8
1 2 3 4 5 6 7 8
1 2577
2 2578
3 2579
4 2580
5 2581
6 2582
[Default = blank (•) blank (•) from address 2577-2582]